Calculating dose‐averaged linear energy transfer in an analytical treatment planning system for carbon‐ion radiotherapy
Journal of Applied Clinical Medical Physics · 2023-02 · 24 (2)
DOI: 10.1002/acm2.13866 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 17.12.2022. Verfasst von Weiwei Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics, Shanghai Proton and Heavy Ion Center, Fudan University Cancer Hospital, Shanghai Key Laboratory of Radiation Oncology …. Hauptthemen laut MEDLINE: Proton Therapy, Heavy Ion Radiotherapy. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Compelling evidence shows the association between the relative biological effectiveness (RBE) of carbon‐ion radiotherapy (CIRT) and the dose averaged linear energy transfer ( LETd ). However, the ability to calculate the LETd in commercially available treatment planning systems (TPS) is lacking.
Purpose
This study aims to develop a method of calculating the LETd of CIRT plans that could be robustly carried out in RayStation (V10B, Raysearch, Sweden).
Methods
The calculation used the fragment spectra in RayStation for the CIRT treatment planning. The dose‐weighted averaging procedure was supported by the microdosimetric kinetic model (MKM). The MKM‐based pencil beam dose engine (PBA, v4.2) for calculating RBE‐weighted doses was reformulated to become a LET ‐weighted calculating engine. A separate module was then configured to inversely calculate the LETd from the absorbed dose of a plan and the associated fragment spectra. In this study, the ion and energy‐specific LET table in the LETd module was further matched with the values decoded from the baseline data of the Syngo TPS (V13C, Siemens, Germany). The LETd distributions of several monoenergetic and modulated beams were calculated and validated against the values derived from the Syngo TPS and the published data.
Results
The differences in LETds of the monoenergetic beams between the new method and the traditional method were within 3% in the entrance and Bragg‐peak regions. However, a larger difference was observed in the distal region. The results of the modulated beams were in good agreement with the works from the published literature.
Conclusions
The method presented herein reformulates the MKM dose engine in the RayStation TPS to inversely calculate LETds . The robustness and accuracy were demonstrated.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Medical Physics, Shanghai Proton and Heavy Ion Center, Fudan University Cancer Hospital, Shanghai Key Laboratory of Radiation Oncology (20dz2261000), Shanghai Engineering Research Center of Proton and Heav…
- Institute of Modern Physics, Applied Ion Beam Physics Laboratory, Fudan University, Shanghai, China.
- Department of Radiation Oncology, Shanghai Proton and Heavy Ion Center, Shanghai Key Laboratory of Radiation Oncology (20dz2261000), Shanghai Engineering Research Center of Proton and Heavy Ion Radiation Therapy, Shangh…
- Department of Medical Physics, Shanghai Proton and Heavy Ion Center, Fudan University Cancer Hospital, Shanghai, China.
ORCID-Profile: Weiwei Wang
Zitieren
APA
Wang, W., Li, P., Shahnazi, K., Wu, X., & Zhao, J. (2023). Calculating dose‐averaged linear energy transfer in an analytical treatment planning system for carbon‐ion radiotherapy. Journal of Applied Clinical Medical Physics, 24(2). https://doi.org/10.1002/acm2.13866
Vancouver
Wang W, Li P, Shahnazi K, Wu X, Zhao J. Calculating dose‐averaged linear energy transfer in an analytical treatment planning system for carbon‐ion radiotherapy. Journal of Applied Clinical Medical Physics. 2023;24(2). doi:10.1002/acm2.13866
BibTeX
@article{Wang2023,
author = {Wang, Weiwei and Li, Ping and Shahnazi, Kambiz and Wu, Xiaodong and Zhao, Jingfang},
title = {Calculating dose‐averaged linear energy transfer in an analytical treatment planning system for carbon‐ion radiotherapy},
journal = {Journal of Applied Clinical Medical Physics},
year = {2023},
volume = {24},
number = {2},
doi = {10.1002/acm2.13866}
}
EUVIMED