Effects of Jute Fiber Length and Dosage on the Workability and Fresh Density of Concrete: An Experimental Investigation
IOSR Journal of Mechanical and Civil Engineering · 2026-05 · 23 (5) · 44-50
DOI: 10.9790/1684-2305034450 ↗Kurz gefasst
Fachartikel in der Zeitschrift IOSR Journal of Mechanical and Civil Engineering, 2026-05. Verfasst von M.I. Ali M.I. Ali und 3 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Jute fiber can alter concrete placement behavior, but reduced fresh density alone does not demonstrate lightweight concrete. This study examined the effects of jute fiber length and dosage on slump and fresh density. Materials and Methods: Concrete mixtures were prepared using volumetric mix proportions of 1:1.5:3 and 1:2:4, incorporating jute fibers of three lengths (10, 15, and 20 mm) at four contents (0, 0.25, 0.50, and 1.00% by weight of cement). Three w/c ratios (0.45, 0.50, and 0.55) were investigated. Workability and fresh-density tests were carried out to evaluate the workability and unit weight of the jute-fiber-modified concrete (JFC). The mix proportions of 1:1.5:3 with w/c ratio of 0.55 were chosen for fresh-density testing based on the slump test results.
Results
Results of the experiments showed that the workability reduced gradually as the jute-fiber length and content increased. An increase in w/c ratio from 0.45 to 0.55 resulted in a decrease in slump while an increase in the mix proportion from 1:1.5:3 to 1:2:4 resulted in an increase in slump. Similarly, for fiber length and content, the fresh density decreased as length increased. The maximum decrease in fresh density was at 20 mm fiber length and 1.00% fiber content and was 2.23% from the control concrete.
Conclusion
The use of jute fibers decreased the workability and fresh density of the concrete, and the amount of decrease increased with the increase of the fiber length and fiber content. Under the tested conditions, the mix proportion of 1:1.5:3 and w/c ratio of 0.55 gave comparatively good workability, and when 20 mm jute fibres were added at 1.00% content, the workability was found to be the lowest due to fresh density. The results are experimental evidence that has been used to select the parameters for jute-fiber to obtain the desired fresh properties of concrete.
Zitieren
APA
Ali, M. A. M., Islam, M. I. M., Ishmum, E. I. E., & Monowar, M. M. M. (2026). Effects of Jute Fiber Length and Dosage on the Workability and Fresh Density of Concrete: An Experimental Investigation. IOSR Journal of Mechanical and Civil Engineering, 23(5), 44-50. https://doi.org/10.9790/1684-2305034450
Vancouver
Ali MAM, Islam MIM, Ishmum EIE, Monowar MMM. Effects of Jute Fiber Length and Dosage on the Workability and Fresh Density of Concrete: An Experimental Investigation. IOSR Journal of Mechanical and Civil Engineering. 2026;23(5):44-50. doi:10.9790/1684-2305034450
BibTeX
@article{Ali2026,
author = {Ali, M.I. Ali M.I. and Islam, M.M Islam M.M and Ishmum, E.I. Ishmum E.I. and Monowar, M.J. Monowar M.J.},
title = {Effects of Jute Fiber Length and Dosage on the Workability and Fresh Density of Concrete: An Experimental Investigation},
journal = {IOSR Journal of Mechanical and Civil Engineering},
year = {2026},
volume = {23},
number = {5},
pages = {44--50},
doi = {10.9790/1684-2305034450}
}
EUVIMED