EUVIMEDEUVIMED entdecken
Crossref

Clinical Assessment Of Obturation Quality And Instrumentation Efficiency Of Two Rotary File Systems Versus Manual Instrumentation In Primary Teeth

Dr. Bidisha Borah, Dr. Bhargab Roymedhi, Dr. Abhishek Khairwa

IOSR Journal of Dental and Medical Sciences · 2026-06 · 25 (6) · 09-12

DOI: 10.9790/0853-2506080912 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IOSR Journal of Dental and Medical Sciences, 2026-06. Verfasst von Dr. Bidisha Borah und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

To compare the effectiveness of traditional hand files and two rotary file systems in terms of obturation quality and instrumentation time during root canal treatment of deciduous molars. Materials and Methods: A sample of 30 primary molars with irreversible pulpitis were taken per group between the age group of 4-8 years. The groups were divided as- Group I(n=30) treated using the Kedo-S File system, Group II(n=30)-treated using Neoendo Pedoflex File system, Group III(n=30)-treated using manual stainless steel K-file(Mani). The amount of time spent instrumenting, the quality of the obturation were documented.

Results

In this present study, Kedo-S rotary file system showed least instrumentation time and highest optimum filled followed by Neoendo PedoFlex rotary file system and Hand K File system.

Conclusion

Pediatric rotary file systems have demonstrated effectiveness in pulpectomies of primary teeth and may serve as a reliable substitute for conventional hand instrumentation, with advantages including improved efficiency and shorter chairside time

Zitieren

APA

Borah, D. B., Roymedhi, D. B., & Khairwa, D. A. (2026). Clinical Assessment Of Obturation Quality And Instrumentation Efficiency Of Two Rotary File Systems Versus Manual Instrumentation In Primary Teeth. IOSR Journal of Dental and Medical Sciences, 25(6), 09-12. https://doi.org/10.9790/0853-2506080912

Vancouver

Borah DB, Roymedhi DB, Khairwa DA. Clinical Assessment Of Obturation Quality And Instrumentation Efficiency Of Two Rotary File Systems Versus Manual Instrumentation In Primary Teeth. IOSR Journal of Dental and Medical Sciences. 2026;25(6):09-12. doi:10.9790/0853-2506080912

BibTeX
@article{Borah2026,
  author = {Borah, Dr. Bidisha and Roymedhi, Dr. Bhargab and Khairwa, Dr. Abhishek},
  title = {Clinical Assessment Of Obturation Quality And Instrumentation Efficiency Of Two Rotary File Systems Versus Manual Instrumentation In Primary Teeth},
  journal = {IOSR Journal of Dental and Medical Sciences},
  year = {2026},
  volume = {25},
  number = {6},
  pages = {09--12},
  doi = {10.9790/0853-2506080912}
}
Kostenlos starten →