Novel Method for Additional Activation of Fixed Functional Appliance (Forsus Fatigue Resistant Device)
IOSR Journal of Dental and Medical Sciences · 2026-06 · 25 (6) · 20-22
DOI: 10.9790/0853-2506052022 ↗Kurz gefasst
Fachartikel in der Zeitschrift IOSR Journal of Dental and Medical Sciences, 2026-06.
Abstract (Originalsprache)
Objective
To propose a reliable method for improving the activation of the Forsus Fatigue Resistant Device in situations where standard crimp activation does not yield satisfactory results. Materials and Methods: A 0.25 mm ligature wire and a bird beak plier are required to effectively secure the push rod.
Results
Wrapping multiple coils of ligature wire around the Forsus Fatigue Resistant Device successfully enhanced its activation, generating higher force levels and exceeding the limitations of traditional crimp activation methods.
Conclusion
This approach offers clinicians a reliable, simple, economical, and time-saving method for achieving effective supplemental activation of the Forsus Fatigue Resistant Device, leading to favorable clinical outcomes.
Zitieren
APA
(2026). Novel Method for Additional Activation of Fixed Functional Appliance (Forsus Fatigue Resistant Device). IOSR Journal of Dental and Medical Sciences, 25(6), 20-22. https://doi.org/10.9790/0853-2506052022
Vancouver
Novel Method for Additional Activation of Fixed Functional Appliance (Forsus Fatigue Resistant Device). IOSR Journal of Dental and Medical Sciences. 2026;25(6):20-22. doi:10.9790/0853-2506052022
BibTeX
@article{euvimed2026,
title = {Novel Method for Additional Activation of Fixed Functional Appliance (Forsus Fatigue Resistant Device)},
journal = {IOSR Journal of Dental and Medical Sciences},
year = {2026},
volume = {25},
number = {6},
pages = {20--22},
doi = {10.9790/0853-2506052022}
}
EUVIMED