Design and simulation verification of a fault escalation and lockout control system for solar charge controllers
IOSR Journal of Electrical and Electronics Engineering · 2026-05 · 21 (5) · 41-50
DOI: 10.9790/0853-2105014150 ↗Kurz gefasst
Fachartikel in der Zeitschrift IOSR Journal of Electrical and Electronics Engineering, 2026-05. Verfasst von C.H. Udeji C.H. Udeji und 2 weiteren Autor:innen.
Abstract (Originalsprache)
The charge controller of a departmental hybrid solar power system is part of a commercial hybrid inverter, whose documentation lists fault codes but does not disclose their trigger thresholds and escalation rules. In this study, a finite state machine for fault escalation and lockout of this charge controller is proposed. The Moore machine was implemented in Verilog-2001 register-transfer-level (RTL) style code with four states (Normal, Warning, Fault, Lockout) and four faults. Overcurrent, overcharge, and overtemperature faults each represent constraints on continuous values (current, voltage, temperature); each has a warning input, an alarm input, and an integrator counter with a threshold reflecting urgency (example values: 3, 7, and 15 clock cycles). Overcurrent escalates fastest and overtemperature slowest. Reverse polarity, a binary condition without thresholds, forces immediate lockout from any state. Once locked out, all active faults are recorded for diagnostics, and leaving requires a manual reset, which is refused while any fault or warning persists. For verification, a self-checking testbench of 33 scenarios, with expected results derived from the specification before code review, was constructed. It passed in full and exercised all 16 specified transitions. Run unchanged against a design with one intentionally altered threshold, it detected the alteration. Verification was by simulation only; no hardware was built.
Zitieren
APA
Udeji, C. U. C., Obute, K. O. K., & Oduyemi, D. O. (2026). Design and simulation verification of a fault escalation and lockout control system for solar charge controllers. IOSR Journal of Electrical and Electronics Engineering, 21(5), 41-50. https://doi.org/10.9790/0853-2105014150
Vancouver
Udeji CUC, Obute KOK, Oduyemi DO. Design and simulation verification of a fault escalation and lockout control system for solar charge controllers. IOSR Journal of Electrical and Electronics Engineering. 2026;21(5):41-50. doi:10.9790/0853-2105014150
BibTeX
@article{Udeji2026,
author = {Udeji, C.H. Udeji C.H. and Obute, K.C. Obute K.C. and Oduyemi, Dr. Olufolahan},
title = {Design and simulation verification of a fault escalation and lockout control system for solar charge controllers},
journal = {IOSR Journal of Electrical and Electronics Engineering},
year = {2026},
volume = {21},
number = {5},
pages = {41--50},
doi = {10.9790/0853-2105014150}
}
EUVIMED