EUVIMEDEUVIMED entdecken
Crossref

Hemodynamic analysis of blood flow in an artery with atherosclerotic stenosis using the finite element method

Israel Isaac Gutiérrez Villegas, Julio Lara García, Belén de Jesús Gutiérrez Armenta, Esiquio Martín Gutiérrez Armenta

IOSR Journal of Computer Engineering · 2026-05 · 28 (5) · 17-23

DOI: 10.9790/0661-2805031723 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IOSR Journal of Computer Engineering, 2026-05. Verfasst von Israel Isaac Gutiérrez Villegas und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A two-dimensional model is presented to compare blood flow in a reference artery and an artery with eccentric stenosis. LDL dynamics serve as the conceptual background; the artery's asymmetric contour was digitized and used to construct the finite element domain. The Navier-Stokes equations for an incompressible fluid were applied; blood was modeled as a Newtonian fluid with a density of 1060 kg/m³ and a viscosity of 0.0035 Pa·s. Boundary conditions included a mean velocity of 0.12 m/s, a no-slip condition at the walls, and zero gauge pressure at the outlet. A triangular mesh was applied separately to the upper and lower walls, without imposing symmetry. With fine discretization, the maximum velocity was 0.279 m/s and the pressure drop was 830.8 Pa (6.231 mmHg). The results show localized acceleration and an increased pressure gradient at the site of the obstruction. This is a computational study and does not constitute a clinical diagnosis.

Background

Atherosclerosis alters vascular geometry and, consequently, the velocity, pressure, and shear stress fields. Computational fluid dynamics enables the analysis of these variables under controlled conditions and complements experimental or clinical interpretation. Materials and Methods: The contour of the original asymmetric artery was digitized and scaled to a length of 5.197 mm and a reference diameter of 1.142 mm. The maximum reduction in luminal height was approximately 62.5%. A Galerkin formulation with a penalty method for incompressibility and triangular elements was applied.

Results

The eccentric stenosis displaced and accelerated the flow core. Sensitivity analysis showed that velocity—and especially the pressure recovered via the penalty method—still depends on mesh refinement; therefore, these values are reported as preliminary numerical estimates.

Conclusion

The finite element model reproduces the expected physical trends of acceleration and pressure loss associated with a reduction in cross-sectional area. Geometric severity should be interpreted in conjunction with pulsatile flow, non-Newtonian rheology, and arterial distensibility in future models.

Zitieren

APA

Villegas, I. I. G., García, J. L., Armenta, B. D. J. G., & Armenta, E. M. G. (2026). Hemodynamic analysis of blood flow in an artery with atherosclerotic stenosis using the finite element method. IOSR Journal of Computer Engineering, 28(5), 17-23. https://doi.org/10.9790/0661-2805031723

Vancouver

Villegas IIG, García JL, Armenta BDJG, Armenta EMG. Hemodynamic analysis of blood flow in an artery with atherosclerotic stenosis using the finite element method. IOSR Journal of Computer Engineering. 2026;28(5):17-23. doi:10.9790/0661-2805031723

BibTeX
@article{Villegas2026,
  author = {Villegas, Israel Isaac Gutiérrez and García, Julio Lara and Armenta, Belén de Jesús Gutiérrez and Armenta, Esiquio Martín Gutiérrez},
  title = {Hemodynamic analysis of blood flow in an artery with atherosclerotic stenosis using the finite element method},
  journal = {IOSR Journal of Computer Engineering},
  year = {2026},
  volume = {28},
  number = {5},
  pages = {17--23},
  doi = {10.9790/0661-2805031723}
}
Kostenlos starten →