High-frequency equipment inhibition of multidrug-resistant Pseudomonas aeruginosa strain
Revista de Ciências Médicas e Biológicas · 23.11.2026 · 24 (1) · 119-124
DOI: 10.9771/cmbio.v24i1.63299 ↗Kurz gefasst
Fachartikel in der Zeitschrift Revista de Ciências Médicas e Biológicas, online erschienen am 23.11.2026. Verfasst von Davi Gonçalves und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Aim
The emergence of antibiotic resistance, mainly due to misuse of antibiotics, has brought forth the need for studies on new approaches to the treatment of bacterial infections and the decontamination of surfaces. High-frequency equipment has been shown to have antibacterial effects due to the formation of ozone during sparking. This method relies on oxidative damage, which could be less effective in strains adapted to resist antibiotics and oxidative agents such as those used in hospital settings. The aim of this study is therefore to evaluate the efficacy of this technique against clinically isolated multidrug-resistant (MDR) or extensively drug-resistant (XDR) Pseudomonas aeruginosa.
Methods
A clinically isolated XDR P. aeruginosa strain and a standard ATCC (American Type Culture Collection) 27853 strain, were spread-plated, divided into three groups, and treated with high-frequency equipment for 0, 5, and 10 minutes prior to incubation. Inhibition was measured through ImageJ, and statistical analysis was performed using GraphPad Prism through ANOVA with Tukey post-test, considering p
Zitieren
APA
Gonçalves, D., Azevedo, J., Gois, L. L., Almeida, P. F. D., Matos, J. B. T. L., & Santos, G. M. P. (2026). High-frequency equipment inhibition of multidrug-resistant Pseudomonas aeruginosa strain. Revista de Ciências Médicas e Biológicas, 24(1), 119-124. https://doi.org/10.9771/cmbio.v24i1.63299
Vancouver
Gonçalves D, Azevedo J, Gois LL, Almeida PFD, Matos JBTL, Santos GMP. High-frequency equipment inhibition of multidrug-resistant Pseudomonas aeruginosa strain. Revista de Ciências Médicas e Biológicas. 2026;24(1):119-124. doi:10.9771/cmbio.v24i1.63299
BibTeX
@article{Gonalves2026,
author = {Gonçalves, Davi and Azevedo, Jailton and Gois, Luana Leandro and Almeida, Paulo Fernando de and Matos, Josilene Borges Torres Lima and Santos, Gustavo Miranda Pires},
title = {High-frequency equipment inhibition of multidrug-resistant Pseudomonas aeruginosa strain},
journal = {Revista de Ciências Médicas e Biológicas},
year = {2026},
volume = {24},
number = {1},
pages = {119--124},
doi = {10.9771/cmbio.v24i1.63299}
}