Sensitivity Improvement of an In-Line Electromagnetic Metal Detector for Chemical Process Streams Using a Radial Basis Function Neural Network
Journal of Chemical Engineering Research Progress · 30.06.2027 · 4 (1) · 45-52
DOI: 10.9767/jcerp.20856 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chemical Engineering Research Progress, online erschienen am 30.06.2027. Verfasst von CholJin O und 5 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).
Abstract (Originalsprache)
Tramp-metal contamination in chemical process streams damages crushers, mills, and extruders, degrades product purity, and can provide ignition sources in combustible-dust atmospheres. In-line electromagnetic induction (EMI) metal detectors are the standard countermeasure, but their practical sensitivity is limited by the product effect—the channel-correlated background signal produced by conductive or moist process materials—which forces conservative detection thresholds and causes false alarms or missed small fragments. This paper presents an in-line EMI metal detector whose sensitivity and false-alarm stability are improved by a radial basis function (RBF) neural network that estimates the size and cross-sectional position of a metallic fragment from the induced voltages of a six-coil array mounted on a process pipe. A prototype was dynamically validated over 200 passes with 125 metallic objects, achieving 99.2% detection accuracy and a 3 mm minimum detectable radius. Because the prototype's component-level documentation is no longer available, a fully parameterized simulation of the in-line configuration was conducted with representative design values and a product-effect model: on 2400 training and 1500 test samples, the RBF network matched a conventional amplitude-threshold detector at the nominal product level (AUC 0.949 versus 0.962) while a two-hidden-layer multilayer perceptron baseline performed comparably (AUC 0.945); the decisive advantage appeared under product-effect drift, where the false-alarm rate of the RBF detector rose to only 20.3% at 2.5× the nominal product level against 71.1% for the amplitude threshold, without recalibration. The RBF estimator also localized fragments with a mean absolute error of 2.0 mm (pipe radius 45 mm), an estimation capability the threshold detector does not provide. These results indicate that a lightweight trained estimator can substantially improve the operability of in-line metal detection in chemical plants. Copyright © 2027 by Authors, Published by Universitas Diponegoro and BCREC Publishing Group. This is an open access article under the CC BY-SA License (https://creativecommons.org/licenses/by-sa/4.0).
Zitieren
APA
O, C., Jo, H., Pak, G., Rim, J., Huang, B., & Huang, C. (2027). Sensitivity Improvement of an In-Line Electromagnetic Metal Detector for Chemical Process Streams Using a Radial Basis Function Neural Network. Journal of Chemical Engineering Research Progress, 4(1), 45-52. https://doi.org/10.9767/jcerp.20856
Vancouver
O C, Jo H, Pak G, Rim J, Huang B, Huang C. Sensitivity Improvement of an In-Line Electromagnetic Metal Detector for Chemical Process Streams Using a Radial Basis Function Neural Network. Journal of Chemical Engineering Research Progress. 2027;4(1):45-52. doi:10.9767/jcerp.20856
BibTeX
@article{O2027,
author = {O, CholJin and Jo, Hyok and Pak, GumHyok and Rim, Jusong and Huang, Boknam and Huang, Cholryong},
title = {Sensitivity Improvement of an In-Line Electromagnetic Metal Detector for Chemical Process Streams Using a Radial Basis Function Neural Network},
journal = {Journal of Chemical Engineering Research Progress},
year = {2027},
volume = {4},
number = {1},
pages = {45--52},
doi = {10.9767/jcerp.20856}
}