Establishing the Validity and Reliability of the Astroskin® Biometric Shirt

Alex MacQuarrie, Jasmin Sidhu, Chloe Deetlefs, Steve Whitfield, Matt Stainer

Topics in Exercise Science and Kinesiology · 12.03.2024 · 5 (1)

DOI: 10.9741/2766-2187.1078 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Topics in Exercise Science and Kinesiology, online erschienen am 12.03.2024. Verfasst von Alex MacQuarrie und 4 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Topics in Exercise Science and Kinesiology Volume 5: Issue 1, Article 4, 2024. Biometric garments such as the Astroskin® biometric shirt (Carre Technologies, Montreal, PQ) may be useful for non-invasively monitoring human physiology in a number of applied settings. The Astroskin® biometric shirt measures and records continuous heart rate (HR), blood oxygenation (SPO2), systolic blood pressure (SBP) and respiratory rate (RR). The aim of this study was to establish the reliability and validity of the Astroskin® biometric shirt. This was achieved through comparing the Astroskin® with a commercially available hospital-grade cardiac monitor, the corpuls3® (Stemple GmbH, Kaufering, Germany) for the following variables: HR, SBP and SPO2. A convenience sample of 24 participants were recruited to participate in two separate data collection sessions. Five did not participate in the second data collection session. Participants were monitored using the Astroskin® while instrumented with the corpuls3® monitor. For both sessions, data were recorded at approximately 1.5-minute intervals over a 22-minute period while the participant was seated comfortably in a chair. Validity of the Astroskin® was assessed by examining mean average percentage error (MAPE) and Lin’s Concordance Correlation Coefficient against pre-established criteria, while Bland-Altman plots showed agreement between the two tools. Reliability between the two sessions was compared using intra-class correlations. The Astroskin® was shown to be extremely valid for HR and performed well for BP and the two systems showed comparable reliability over time. With SPO2 the MAPE and bias were good, but concordance was low, and the Astroskin® was not as reliable as the corpuls3®. Results indicated that the Astroskin® biometric shirt was a valid instrument compared to the corpuls3® monitor utilising participants in a sedentary setting. More research is recommended for the Astroskin® in a variety of applied settings to confirm its validity.

Zitieren

APA

MacQuarrie, A., Sidhu, J., Deetlefs, C., Whitfield, S., & Stainer, M. (2024). Establishing the Validity and Reliability of the Astroskin® Biometric Shirt. Topics in Exercise Science and Kinesiology, 5(1). https://doi.org/10.9741/2766-2187.1078

Vancouver

MacQuarrie A, Sidhu J, Deetlefs C, Whitfield S, Stainer M. Establishing the Validity and Reliability of the Astroskin® Biometric Shirt. Topics in Exercise Science and Kinesiology. 2024;5(1). doi:10.9741/2766-2187.1078

BibTeX
@article{MacQuarrie2024,
  author = {MacQuarrie, Alex and Sidhu, Jasmin and Deetlefs, Chloe and Whitfield, Steve and Stainer, Matt},
  title = {Establishing the Validity and Reliability of the Astroskin® Biometric Shirt},
  journal = {Topics in Exercise Science and Kinesiology},
  year = {2024},
  volume = {5},
  number = {1},
  doi = {10.9741/2766-2187.1078}
}
Kostenlos starten →