EUVIMEDEUVIMED entdecken
Crossref

Computational Dead Time Correction in Fluorescence Lifetime Imaging Microscopy (FLIM)

Yidan Yin

Open Scholarship Institutional Repository (Washington University in St. Louis) · 08.07.2025

DOI: 10.7936/x85y-x223 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Open Scholarship Institutional Repository (Washington University in St. Louis), erschienen am 08.07.2025. Verfasst von Yidan Yin.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fluorescence Lifetime Imaging Microscopy (FLIM) is a crucial tool in biomedical research. It can visualize and measure molecular interactions and cellular processes by analyzing the fluorescence decay of molecules in biological samples. Unlike traditional imaging methods based on fluorescence intensity, FLIM uses fluorescence lifetime - the time delay between excitation and emission in the fluorescence process - to provide detailed information about the biochemical environment and molecular activity. In photon-counting systems, dead time is the short period after detecting a photon when the detection system cannot record new photons. The effect of dead time on the measured fluorescence intensity and lifetime is highly dependent on the photon rate (the number of incident photons per laser period). Dead time causes photon counts to be underestimated, especially at high photon rates, leading to errors in both fluorescence intensity and lifetime measurements. To address this issue, the Cross-Cycle computational correction method, inspired by techniques from Light Detection and Ranging (LiDAR) systems, has been developed to correct for dead time effects. The Cross-Cycle method statistically models the loss of photons within and across laser cycles, estimates the probability of photon detection, and reconstructs fluorescence intensity and lifetime. Here, we demonstrate that the Cross-Cycle method improves the accuracy of fluorescence intensity and lifetime in simulated data. This correction allows more accurate fluorescence intensity and lifetime estimation at high photon rates, enabling faster imaging and more reliable results in FLIM.

Schlagwörter

fluorescence lifetime imagingdead time correctionphoton countingphoton detection probability

Zitieren

APA

Yin, Y. (2025). Computational Dead Time Correction in Fluorescence Lifetime Imaging Microscopy (FLIM). Open Scholarship Institutional Repository (Washington University in St. Louis). https://doi.org/10.7936/x85y-x223

Vancouver

Yin Y. Computational Dead Time Correction in Fluorescence Lifetime Imaging Microscopy (FLIM). Open Scholarship Institutional Repository (Washington University in St. Louis). 2025. doi:10.7936/x85y-x223

BibTeX
@article{Yin2025,
  author = {Yin, Yidan},
  title = {Computational Dead Time Correction in Fluorescence Lifetime Imaging Microscopy (FLIM)},
  journal = {Open Scholarship Institutional Repository (Washington University in St. Louis)},
  year = {2025},
  doi = {10.7936/x85y-x223}
}
Kostenlos starten →