Percutaneous Pulmonary Valve Replacement in Native Right Ventricular Outflow Tract.One-Step Technique Using a Balloon-Expandable Valve: Initial Experience in Argentina
Revista Argentina de Cardiologia · 30.12.2025 · 93 (6) · 439-455
DOI: 10.7775/rac.v93.i6.20952 ↗Kurz gefasst
Fachartikel in der Zeitschrift Revista Argentina de Cardiologia, erschienen am 30.12.2025. Verfasst von Alejandro Peirone und 7 weiteren Autor:innen.
Abstract (Originalsprache)
Background
The adverse impact of pulmonary valve incompetence (PVI) has been extensively studied in patients with tetralogy of Fallot (TOF) after surgical repair. Percutaneous pulmonary valve replacement (PPVR) with balloon-expandable and self-expanding valves is an alternative to surgical reintervention.
Objective
The aim of this study is to report on the initial experience of PPVR using a one-step implantation technique with a balloon-expandable heart valve in Argentina.
Methods
We conducted an observational and descriptive study of all consecutive patients treated with PPVR due to severe and/ or free PVI with signs of right ventricular dilation/dysfunction who underwent transannular patch repair as part of the initial correction of their congenital heart disease. The one-step technique was defined as valve implantation in the native right ventricular outflow tract (RVOT) without prior stent placement to prepare the landing zone. A balloon-expandable Myval® valve (Meril LifeS-cience, India) was implanted in all cases.
Results
From July 2023 to April 2025, 10 patients (8 males) underwent PPVR. Three patients had previously required stenting of the left pulmonary artery branch. Median age and weight were 20 years (interquartile range, IQR, 12.5–34.3) and 61.3 kg (33.7–77.2), respectively. All patients were in functional class II. Valve implantation was successful in all cases. None of the patients exhibited significant RVOT gradient or PVI immediately after valve implantation. One patient presented mild paravalvular leak immediately after valve implantation and another increased the gradient 7 months after implantation. After a median follow-up of 6.7 months (1.2-15.7), PVI remained grade 0 in all patients and mean peak systolic gradient across the valve, estimated by color Doppler, was 21.8 mm Hg (15-30.1). There were no cases of valve displacements and/or fractures, episodes of arrhythmias, infective endocarditis, need for valve explantation, or deaths during short-and mid-term follow-up.
Conclusions
Percutaneous pulmonary valve replacement in native RVOT using a one-step technique with a balloon-expandable valve is feasible, safe and efficient in this preliminary experience in Argentina. Inmediate restoration of pulmonary valve competence was observed after implantation.
Zitieren
APA
Peirone, A., Contreras, A., Cabrera, M., Allub, A., Juaneda, E., Bueno, N., Banille, E., & Juaneda, I. (2025). Percutaneous Pulmonary Valve Replacement in Native Right Ventricular Outflow Tract.One-Step Technique Using a Balloon-Expandable Valve: Initial Experience in Argentina. Revista Argentina de Cardiologia, 93(6), 439-455. https://doi.org/10.7775/rac.v93.i6.20952
Vancouver
Peirone A, Contreras A, Cabrera M, Allub A, Juaneda E, Bueno N, et al. Percutaneous Pulmonary Valve Replacement in Native Right Ventricular Outflow Tract.One-Step Technique Using a Balloon-Expandable Valve: Initial Experience in Argentina. Revista Argentina de Cardiologia. 2025;93(6):439-455. doi:10.7775/rac.v93.i6.20952
BibTeX
@article{Peirone2025,
author = {Peirone, Alejandro and Contreras, Alejandro and Cabrera, Marcelo and Allub, Alejandro and Juaneda, Erneso and Bueno, Nora and Banille, Edgardo and Juaneda, Ignacio},
title = {Percutaneous Pulmonary Valve Replacement in Native Right Ventricular Outflow Tract.One-Step Technique Using a Balloon-Expandable Valve: Initial Experience in Argentina},
journal = {Revista Argentina de Cardiologia},
year = {2025},
volume = {93},
number = {6},
pages = {439--455},
doi = {10.7775/rac.v93.i6.20952}
}
EUVIMED