Structural strengthening of large-span industrial building roofs through a span-shortening strategy

Tiago Martins, Isabel Nieves-Otero, Alejandra Sanchez-Rubio, Jaime Fernández-Gómez

Revista Ingeniería de Construcción · 06.08.2026 · 41 (2) · 1-13

DOI: 10.7764/ric.00178.21 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Revista Ingeniería de Construcción, online erschienen am 06.08.2026. Verfasst von Tiago Martins und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The use of span shortening elements, generally made of steel, is a common structural reinforcement technique in building intended for residential or commercial use, although it is not so common in the industrial field. This is mainly due to the challenges imposed by strength and stiffness requirements involved in their use in structures where spans are typically significantly higher than those found in conventional buildings. Additionally, there are conditioning factors inherent to the nature of industrial buildings, such as clearance limitations, the need to avoid obstructing facade openings, the passage of ducts, etc. This work presents how the use of this technique, provided it is properly designed and does not pose an insurmountable obstacle to the use of the building, can also be of interest in structures of this nature. Such situations arise particularly in industrial buildings where, due to demands exceeding the originally planned loads, or due to inadequate design during the project phase (if detected in time), it becomes necessary to implement an agile reinforcement intervention that provides additional load-bearing capacity to existing horizontal structures, offering a viable alternative to full replacement. Nowadays, increased structural demands are often caused by the installation of rooftop HVAC systems, such as solar panels or air handling units, driven by sustainability and energy efficiency requirements. Based on the case study of an industrial building located in Madrid (Spain), where the roof loads considered during the design phase were found to be lower than the actual service load demands, and following an initial strengthening intervention using FRP laminates that proved insufficient, this paper analyses the design parameters and structural constraints that enabled the implementation of mullions as a reinforcement technique in this type of building. The study also highlights the feasibility of applying this solution to similar cases in the future.

Zitieren

APA

Martins, T., Nieves-Otero, I., Sanchez-Rubio, A., & Fernández-Gómez, J. (2026). Structural strengthening of large-span industrial building roofs through a span-shortening strategy. Revista Ingeniería de Construcción, 41(2), 1-13. https://doi.org/10.7764/ric.00178.21

Vancouver

Martins T, Nieves-Otero I, Sanchez-Rubio A, Fernández-Gómez J. Structural strengthening of large-span industrial building roofs through a span-shortening strategy. Revista Ingeniería de Construcción. 2026;41(2):1-13. doi:10.7764/ric.00178.21

BibTeX
@article{Martins2026,
  author = {Martins, Tiago and Nieves-Otero, Isabel and Sanchez-Rubio, Alejandra and Fernández-Gómez, Jaime},
  title = {Structural strengthening of large-span industrial building roofs through a span-shortening strategy},
  journal = {Revista Ingeniería de Construcción},
  year = {2026},
  volume = {41},
  number = {2},
  pages = {1--13},
  doi = {10.7764/ric.00178.21}
}
Kostenlos starten →