EUVIMEDEUVIMED entdecken
Open Access

Use of N-hexyl Cyanoacrylate Monomers for the Treatment of Intra- and Extracranial Arteriovenous Malformations: A Single-Center Experience

Eduardo Murias Quintana, José Rodríguez Castro, Josep Puig, Alberto Gil García, René Chapot, Víctor Maestro, Juan Carlos Llibre, Julio Cesar Gutiérrez Morales, Faustino García Arias, Pedro Vega

Cureus · 17.05.2025

DOI: 10.7759/cureus.84290 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cureus, erschienen am 17.05.2025. Verfasst von Eduardo Murias Quintana und 9 weiteren Autor:innen. Beteiligte Einrichtung: Interventional Neuroradiology, Hospital Universitario Central de Asturias, Oviedo, ESP. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Liquid embolic agents (LEAs) are commonly used in the endovascular treatment of vascular malformations for their penetration, visibility, and reflux control. This study presents our experience with N-hexyl cyanoacrylate (NHCA), also known as "Magic Glue," and its strengths and limitations. METHODS: A retrospective single-center case series study was conducted to assess outcomes among patients with complex head and neck vascular lesions treated with NHCA injection at Hospital Universitario Central de Asturias, Oviedo, Spain, between January 2022 and December 2023. Procedure and outcome measures included justification for using NHCA, technical success (defined as the outcome achieved based on objective), materials used for catheterization, dilution ratio of NHCA, and observations of technical significance during the procedure. RESULTS: A total of 24 NHCA injections were performed in 22 patients with intra- and extracranial vascular lesions. An arteriovenous malformation (AVM) was treated in 83.3% (20/24) of cases, including nidal pseudoaneurysms in ruptured AVMs (8/24, 33.3%), arterial feeder embolization in AVM treatment (7/24, 29.2%), and single-feeder AVMs (5/24, 20.8%). The remaining cases included bone or skin vascular malformations (2/24, 8.3%) and dural arteriovenous fistulas (2/24, 8.3%). In 87.5% (21/24) of cases, procedures were successful using a 1:4 dilution ratio of NHCA in lipiodol. In 70.8% (17/24) of cases, the HeadWay Duo 167 cm microcatheter was used to gain arterial access, and the Magic 1.2F 165 cm microcatheter was used in the remaining cases. Injection durations ranged from 27 seconds to 9 minutes and 38 seconds. No clinically significant complications occurred, and microcatheter retrieval was successful in 100% of cases. Complete occlusion with a single NHCA injection into the arterial feeder was achieved in 12.5% (3/24) of cases. NHCA demonstrated optimal penetration and advancement capacity in both intranidal and proximal injections, allowing effective embolization of complex vascular structures. CONCLUSION: NHCA demonstrated safe and effective penetration and advancement in both intranidal and proximal injections, allowing successful embolization of complex vascular structures. Further research is necessary to establish its long-term efficacy and optimize its clinical applications.

Schlagwörter

Stichwörter der Autor:innen

embolic toolendovascular treatmentnhca (n-hexyl cyanoacrylate) monomerssafetyvascular malformations

Autor:innen und Institutionen

  • Interventional Neuroradiology, Hospital Universitario Central de Asturias, Oviedo, ESP.
  • Interventional Neuroradiology Chair of the University of Oviedo (CENIT), Universidad de Oviedo, Oviedo, ESP.
  • Interventional Neuroradiology, Hospital Clínic de Barcelona, Barcelona, ESP.
  • Interventional Neuroradiology, Hospital Universitario Marqués de Valdecilla, Santander, ESP.
  • Interventional Neuroradiology, Alfried Krupp Krankenhaus, Essen, DEU.
  • Interventional Neuroradiology, Hospital Universitario de Salamanca, Salamanca, ESP.

Zitieren

APA

Murias Quintana, E., Rodríguez Castro, J., Puig, J., Gil García, A., Chapot, R., Maestro, V., Llibre, J. C., Gutiérrez Morales, J. C., García Arias, F., & Vega, P. (2025). Use of N-hexyl Cyanoacrylate Monomers for the Treatment of Intra- and Extracranial Arteriovenous Malformations: A Single-Center Experience. Cureus. https://doi.org/10.7759/cureus.84290

Vancouver

Murias Quintana E, Rodríguez Castro J, Puig J, Gil García A, Chapot R, Maestro V, et al. Use of N-hexyl Cyanoacrylate Monomers for the Treatment of Intra- and Extracranial Arteriovenous Malformations: A Single-Center Experience. Cureus. 2025. doi:10.7759/cureus.84290

BibTeX
@article{MuriasQuintana2025,
  author = {Murias Quintana, Eduardo and Rodríguez Castro, José and Puig, Josep and Gil García, Alberto and Chapot, René and Maestro, Víctor and Llibre, Juan Carlos and Gutiérrez Morales, Julio Cesar and García Arias, Faustino and Vega, Pedro},
  title = {Use of N-hexyl Cyanoacrylate Monomers for the Treatment of Intra- and Extracranial Arteriovenous Malformations: A Single-Center Experience},
  journal = {Cureus},
  year = {2025},
  doi = {10.7759/cureus.84290}
}
Kostenlos starten →