Fachartikel in der Zeitschrift Cureus, erschienen am 25.12.2024. Verfasst von Vipul Sharma und 9 weiteren Autor:innen. Beteiligte Einrichtung: Artificial Intelligence, Monere AI, Delhi, IND. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Anemia, a critical public health issue, affects nearly two billion people globally. Frequent monitoring of blood hemoglobin levels is essential for managing its burden. While point-of-care testing (POCT) devices facilitate hemoglobin testing in resource-limited settings, most are invasive and have inherent limitations. The Non-Invasive Anemia Detection App (NiADA) (Monere, UT) offers a non-invasive alternative, utilizing artificial intelligence (AI) to estimate hemoglobin levels from images of the lower eyelid. This low-cost, real-time solution employs a custom computer vision deep-learning algorithm for hemoglobin levels, offering significant potential for early diagnosis and management of anemia.

Methods

This study evaluated NiADA in two phases. In the first phase, its performance was compared to laboratory measurements and the minimally invasive POCT device, Hemocue Hb 301. In this study, the current version of NiADA version 2 (V2) is also compared against the previous version of NiADA version 1 (V1) to show the improvement in the last six months. In the second phase, NiADA's results were compared against hemoglobin estimations made by a group of medical professionals, as well as against lab analyzers. For both phases, NiADA performance was evaluated using the Bland-Altman plot, regression coefficients, percentage of acceptable limit, Pearson correlation coefficient, and Lin's concordance correlation coefficient.

Results

The mean difference between NiADA-V2 and laboratory-estimated hemoglobin values was -0.11 g/dL, with limits of agreement (LOA) ranging from +2.86 to -2.64 g/dL, where the upper limit is comparable with HemoCue. The NiADA-V2-acceptable range (percentage of samples falling within ±1 g/dL absolute error) increased to 54% compared to 40% in NiADA-V1. Additionally, NiADA outperformed medical professionals, showing a mean difference of 0.07 g/dL compared to medical professionals' 0.42 g/dL.

Conclusion

NiADA, as a non-invasive application, exhibits performance comparable to minimally invasive tools and other POCT devices. Its accuracy exceeds that of medical professionals, making it a viable option for anemia screening and monitoring, particularly in community medicine and regions with limited healthcare resources.

Schlagwörter

Stichwörter der Autor:innen

anemiaartificial intelligencehemoglobin monitoringimage processingnon-invasivesmart phone app

Autor:innen und Institutionen

  • Artificial Intelligence, Monere AI, Delhi, IND.
  • Artificial Intelligence, Monere AI, Kolkata, IND.
  • Pathology, ESI Corporation Medical College and Hospital, Kolkata, IND.
  • Uro-Oncology and Robotics, HCG Cancer Centre, Kolkata, IND.
  • Medicine, North Bengal Medical College and Hospital, Siliguri, IND.
  • Community Medicine and Family Medicine, All India Institute of Medical Sciences, Kalyani, IND.

Zitieren

APA

Sharma, V., Das, D., Sarkar, S., Das, S., Sherpa, P. L., Ray, A., Ahamed, F., Nandi, J., Nandi, M., & Banerjee, K. (2024). Enhancing Anemia Detection With Non-invasive Anemia Detection With AI (NiADA): Insights From Clinical Validations and Physician Observations. Cureus. https://doi.org/10.7759/cureus.76369

Vancouver

Sharma V, Das D, Sarkar S, Das S, Sherpa PL, Ray A, et al. Enhancing Anemia Detection With Non-invasive Anemia Detection With AI (NiADA): Insights From Clinical Validations and Physician Observations. Cureus. 2024. doi:10.7759/cureus.76369

BibTeX
@article{Sharma2024,
  author = {Sharma, Vipul and Das, Debjeet and Sarkar, Sagarika and Das, Suvraraj and Sherpa, Pasang Lahmu and Ray, Arpan and Ahamed, Farhad and Nandi, Jhuma and Nandi, Mou and Banerjee, Krishanu},
  title = {Enhancing Anemia Detection With Non-invasive Anemia Detection With AI (NiADA): Insights From Clinical Validations and Physician Observations},
  journal = {Cureus},
  year = {2024},
  doi = {10.7759/cureus.76369}
}
Kostenlos starten →