EUVIMEDEUVIMED entdecken
Open Access

Assessment of the Antibiofilm Performance of Silver-Containing Wound Dressings: A Dual-Species Biofilm Model

Kate Meredith, Matilda M Coleborn, Lucy E Forbes, Daniel G Metcalf

Cureus · 24.09.2024

DOI: 10.7759/cureus.70086 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cureus, erschienen am 24.09.2024. Verfasst von Kate Meredith und 3 weiteren Autor:innen. Beteiligte Einrichtung: Research and Development, Convatec, Deeside, GBR. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

It is commonly accepted that microorganisms found within hard-to-heal wounds are present in biofilm form. Biofilms are often polymicrobial in nature, which increases their virulence and tolerance to antimicrobial agents. The aim of this study was to compare the antibiofilm activity of silver-containing antimicrobial wound dressings in a dual-species simulated wound biofilm model. Materials and methods Four silver-containing wound dressings were evaluated in vitro: Aquacel® Ag+ Extra™ dressing, KerraContact® Ag dressing, Durafiber* Ag dressing, and UrgoClean Ag dressing. Each dressing was applied to a simulated wound assembly containing biofilm-gauze inoculated with Klebsiella pneumoniae and methicillin-resistant Staphylococcus aureus (MRSA). Each biofilm-inoculated gauze was incubated at 35±3ºC for 6, 24, 48 and 72 hours. Enumeration of surviving biofilm bacteria at each time point was performed in triplicate for each test dressing and its equivalent control.

Results

Aquacel® Ag+ Extra™ dressing was observed to reduce the biofilm population within 24 hours with a >4 log10 kill observed for K. pneumoniae and >6 log10 for MRSA from an initial biofilm challenge of 4.16×109 CFU/mL. This kill rate was sustained for the duration of the challenge period, with Aquacel® Ag+ Extra™ dressing reducing the biofilm population to non-detectable levels (

Schlagwörter

Stichwörter der Autor:innen

biofilmdressingshard-to-healklebsiella pneumoniaemethicillin-resistant staphylococcus aureusmrsasilverwound

Autor:innen und Institutionen

  • Research and Development, Convatec, Deeside, GBR.

Zitieren

APA

Meredith, K., Coleborn, M. M., Forbes, L. E., & Metcalf, D. G. (2024). Assessment of the Antibiofilm Performance of Silver-Containing Wound Dressings: A Dual-Species Biofilm Model. Cureus. https://doi.org/10.7759/cureus.70086

Vancouver

Meredith K, Coleborn MM, Forbes LE, Metcalf DG. Assessment of the Antibiofilm Performance of Silver-Containing Wound Dressings: A Dual-Species Biofilm Model. Cureus. 2024. doi:10.7759/cureus.70086

BibTeX
@article{Meredith2024,
  author = {Meredith, Kate and Coleborn, Matilda M and Forbes, Lucy E and Metcalf, Daniel G},
  title = {Assessment of the Antibiofilm Performance of Silver-Containing Wound Dressings: A Dual-Species Biofilm Model},
  journal = {Cureus},
  year = {2024},
  doi = {10.7759/cureus.70086}
}