EUVIMEDEUVIMED entdecken
Open Access

Radial Arterial Cannulation by Ultrasound-Guided Dynamic Needle-Tip Positioning Using the Short-Axis Out-of-Plane Approach Versus the Long-Axis In-Plane Approach: A Randomized Controlled Study

Bharath Kumar Mesa, Mamta Sinha, Mayank Kumar, Sarita Ramchandani, Chandan Dey, Nandkishore Agrawal, Monica Khetarpal

Cureus · 14.02.2024

DOI: 10.7759/cureus.54183 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cureus, erschienen am 14.02.2024. Verfasst von Bharath Kumar Mesa und 6 weiteren Autor:innen. Beteiligte Einrichtung: Anesthesiology, All India Institute of Medical Sciences, Raipur, Raipur, IND. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Radial artery cannulation is a commonly performed invasive procedure for assessing a patient's hemodynamic status and collecting blood samples. Ultrasound guidance has shown benefits in improving the success rate of first-attempt cannulation. Two main approaches, short-axis out-of-plane (SAOOP) and long-axis in-plane (LAIP), are commonly used. A modified technique called dynamic needle-tip positioning (DNTP) using the short-axis out-of-plane approach has been reported to enhance arterial catheterization. This study aims to compare the first-attempt success rates of radial artery cannulation using the two techniques, DNTP versus LAIP, along with overall success rates, cannulation time, and number of attempts.

Methods

This prospective, randomized, controlled, clinical study was conducted after obtaining clearance from the Institute Ethics Committee of AIIMS, Raipur. Ninety-six patients between the ages of 18 and 50 years, undergoing elective surgery under general anesthesia, and required radial arterial cannulation were randomized and equally allocated into two groups as the LAIP and DNTP approaches. The first-pass success rate, time to achieve successful cannulation, number of attempts needed, overall success rate within five minutes, and potential complications, such as thrombosis, vasospasm, and hematoma, were recorded.

Results

A total of 96 patients were included, with 48 in the LAIP group and 48 in the DNTP group. The DNTP group showed statistically significant advantages over the LAIP group, with a higher first-pass success rate (97.9% vs. 83.3%; p = 0.014) and shorter time to achieve successful cannulation (9.29±3.79 vs. 26.16±20.22 seconds; p = 0.001).

Conclusion

The ultrasound-guided short-axis DNTP technique for radial artery cannulation demonstrated a significant advantage as compared to the LAIP technique. The DNTP technique resulted in higher first-attempt cannulation success and shorter cannulation time.

Schlagwörter

Stichwörter der Autor:innen

dynamic needle tip positioningfirst pass successlong axis approachradial artery cannulationshort axis approachultrasound

Autor:innen und Institutionen

  • Anesthesiology, All India Institute of Medical Sciences, Raipur, Raipur, IND.
  • Emergency Medicine and Trauma, All India Institute of Medical Sciences, Raipur, Raipur, IND.

Zitieren

APA

Mesa, B. K., Sinha, M., Kumar, M., Ramchandani, S., Dey, C., Agrawal, N., & Khetarpal, M. (2024). Radial Arterial Cannulation by Ultrasound-Guided Dynamic Needle-Tip Positioning Using the Short-Axis Out-of-Plane Approach Versus the Long-Axis In-Plane Approach: A Randomized Controlled Study. Cureus. https://doi.org/10.7759/cureus.54183

Vancouver

Mesa BK, Sinha M, Kumar M, Ramchandani S, Dey C, Agrawal N, et al. Radial Arterial Cannulation by Ultrasound-Guided Dynamic Needle-Tip Positioning Using the Short-Axis Out-of-Plane Approach Versus the Long-Axis In-Plane Approach: A Randomized Controlled Study. Cureus. 2024. doi:10.7759/cureus.54183

BibTeX
@article{Mesa2024,
  author = {Mesa, Bharath Kumar and Sinha, Mamta and Kumar, Mayank and Ramchandani, Sarita and Dey, Chandan and Agrawal, Nandkishore and Khetarpal, Monica},
  title = {Radial Arterial Cannulation by Ultrasound-Guided Dynamic Needle-Tip Positioning Using the Short-Axis Out-of-Plane Approach Versus the Long-Axis In-Plane Approach: A Randomized Controlled Study},
  journal = {Cureus},
  year = {2024},
  doi = {10.7759/cureus.54183}
}
Kostenlos starten →