Sonographic Characteristics and Pathology Correlation of Breast Imaging Reporting and Data System (BI-RADS) Category 4 Lesions

Poonum Khan, Imrana Masroor, Muhammad S Alam, Abdus Salam, Yasir Ali, Muhammad Salman Khan

Cureus · 31.12.2023

DOI: 10.7759/cureus.51410 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cureus, erschienen am 31.12.2023. Verfasst von Poonum Khan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Radiology, Aga Khan University, Karachi, PAK. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: The Breast Imaging-Reporting and Database System (BI-RADS) category 4 is designated for breast lumps that do not display the typical features of malignancy but still raise enough suspicion to warrant a recommendation for a biopsy, as malignancy cannot be ruled out through imaging alone. The main objective of this study was to investigate the sonographic characteristics and pathology correlation of BI-RADS 4 breast lesions and determine the positive predictive rate of BI-RADS 4 lesions in diagnosing breast cancer, using histopathology as the gold standard. METHODS: This was a cross-sectional study conducted at the Department of Radiology, Aga Khan University Hospital in Karachi, spanning from May 2021 to August 2022, with a duration of 15 months. The study focused on female patients over the age of 18 who presented with suspicious breast lesions on ultrasound. Both mammography and ultrasound-guided core needle biopsy were performed on these patients, followed by a detailed histopathological evaluation of the biopsy specimens. To calculate the positive predictive value (PPV), true positive cases were identified through both histopathology and ultrasonography. RESULTS: A total of 227 cases were categorized as BI-RADS 4 lesions, with the patients' mean age being 47.8 ± 14.3 years (range: 17 - 88). Among the biopsied lesions, 101 cases were confirmed to be true positive for breast malignancies, resulting in a PPV for malignancy of 44.9%. Conversely, there were 124 false positive cases out of the 227 BI-RADS 4 category lesions (54.63%). The primary indication for presentation was a breast lump, and out of the 101 confirmed malignant cases, 70 (69.3%) were associated with malignancy. CONCLUSION: BI-RADS 4 can be utilized to assess suspicious breast lumps; however, for more reliable results and to avoid false negatives, histopathological confirmation should complement the imaging findings.

Schlagwörter

Stichwörter der Autor:innen

bi-rads 4breast cancer diagnosishistopathologymammographyultrasound-guided biopsy

Autor:innen und Institutionen

  • Radiology, Aga Khan University, Karachi, PAK.
  • Radiology, King Faisal Specialist Hospital and Research Centre, Medina, SAU.
  • Internal Medicine, Khyber Teaching Hospital, Peshawar, PAK.
  • Internal Medicine, Nazareth Hospital, Philadelphia, USA.
  • Diagnostic and Interventional Imaging, University of Texas Health Science Center at Houston, Houston, USA.

Zitieren

APA

Khan, P., Masroor, I., Alam, M. S., Salam, A., Ali, Y., & Khan, M. S. (2023). Sonographic Characteristics and Pathology Correlation of Breast Imaging Reporting and Data System (BI-RADS) Category 4 Lesions. Cureus. https://doi.org/10.7759/cureus.51410

Vancouver

Khan P, Masroor I, Alam MS, Salam A, Ali Y, Khan MS. Sonographic Characteristics and Pathology Correlation of Breast Imaging Reporting and Data System (BI-RADS) Category 4 Lesions. Cureus. 2023. doi:10.7759/cureus.51410

BibTeX
@article{Khan2023,
  author = {Khan, Poonum and Masroor, Imrana and Alam, Muhammad S and Salam, Abdus and Ali, Yasir and Khan, Muhammad Salman},
  title = {Sonographic Characteristics and Pathology Correlation of Breast Imaging Reporting and Data System (BI-RADS) Category 4 Lesions},
  journal = {Cureus},
  year = {2023},
  doi = {10.7759/cureus.51410}
}
Kostenlos starten →