Twelve-Month Fusion Outcomes of Three- and Four-Level Anterior Cervical Discectomy and Fusion Using a 3D-Printed Fully Porous Polyetheretherketone Interbody Implant
Cureus · 19.11.2026
DOI: 10.7759/cureus.119952 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cureus, erschienen am 19.11.2026. Verfasst von Christopher C Harrod und 4 weiteren Autor:innen. Die Arbeit nennt 41 Literaturangaben.
Abstract (Originalsprache)
Background
When conservative treatments fail to treat cervical degenerative disc disease (DDD) and/or instability, anterior cervical discectomy and fusion (ACDF) is a widely used and effective surgical approach. ACDF is commonly performed for one- or two-level cervical disc disease but is increasingly used to treat multi-level pathology, as degenerative cervical spine pathology may affect three or more levels. However, data regarding the radiographic outcomes of long-segment (≥3-level) ACDF using contemporary-era interbody implants are limited. This study aimed to report 12-month fusion rate outcomes following three- and four-level ACDF using a novel 3D-printed, fully porous, trabecular polyetheretherketone (PEEK) interbody implant.
Methods
This ambispective cohort study included 43 patients identified from a consecutive surgical series who underwent three- or four-level ACDF using the 3D-printed porous PEEK interbody implant and anterior plating. Twelve-month postoperative outcomes are reported. Fusion status was assessed using CT by multiple independent, blinded reviewers, flexion/extension X-ray analysis, and a composite score of both.
Results
A total of 43 patients (152 treated levels), with a mean age of 61.5 years and a mean BMI of 31.2, were included. Twenty-three patients (53.5%) underwent a four-level ACDF, and 20 (46.5%) underwent a three-level ACDF. Successful fusion was observed at 95.4% of treated levels. On a per-patient basis, 86% were fused by CT at all treated levels.
Conclusion
This 3D-printed, fully porous trabecular PEEK interbody implant achieved high fusion across both per-level and per-patient assessments in three- and four-level ACDF at 12 months, with low rates of revision or symptomatic nonunion. These findings support its use in long-segment cervical reconstruction, though longer-term follow-up is warranted to confirm the durability of fusion.
Zitieren
APA
Harrod, C. C., Slosar, P., Lucyk, I., O'Brien, A., & Stone, M. B. (2026). Twelve-Month Fusion Outcomes of Three- and Four-Level Anterior Cervical Discectomy and Fusion Using a 3D-Printed Fully Porous Polyetheretherketone Interbody Implant. Cureus. https://doi.org/10.7759/cureus.119952
Vancouver
Harrod CC, Slosar P, Lucyk I, O'Brien A, Stone MB. Twelve-Month Fusion Outcomes of Three- and Four-Level Anterior Cervical Discectomy and Fusion Using a 3D-Printed Fully Porous Polyetheretherketone Interbody Implant. Cureus. 2026. doi:10.7759/cureus.119952
BibTeX
@article{Harrod2026,
author = {Harrod, Christopher C and Slosar, Paul and Lucyk, Isabella and O'Brien, Adaire and Stone, Marcus B},
title = {Twelve-Month Fusion Outcomes of Three- and Four-Level Anterior Cervical Discectomy and Fusion Using a 3D-Printed Fully Porous Polyetheretherketone Interbody Implant},
journal = {Cureus},
year = {2026},
doi = {10.7759/cureus.119952}
}
EUVIMED