EUVIMEDEUVIMED entdecken
Crossref

Cross-Dataset Reliability of Chest Radiograph Models: A Provenance-Aware Evaluation of Performance and Thresholds

Sadman Haque Sakib, Sharmin Akter Poppy, Murtaza Hussain Shaikh, Najmuddin ., Md Anik Hosan, Irin Jahan Sorna, Sk Rakib Ul Islam Rahat

Cureus · 17.11.2026

DOI: 10.7759/cureus.119832 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cureus, erschienen am 17.11.2026. Verfasst von Sadman Haque Sakib und 6 weiteren Autor:innen. Die Arbeit nennt 13 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Public chest radiograph datasets attach different label meanings and sources to findings such as pneumonia and lung opacity. A shared label name does not ensure that models are being evaluated against the same target.

Objective

The objective of this study was to compare discrimination, calibration, high-confidence errors, and source-threshold flag volume across four public chest radiograph tasks.

Methods

Four dataset-defined tasks were evaluated: Kaggle/Kermany pneumonia, Radiological Society of North America (RSNA) lung opacity, CheXpert pneumonia, and CheXpert lung opacity. For each image, probabilities from five saved DenseNet-121 seeds per source task were averaged. Each resulting ensemble was evaluated on all four held-out target splits, producing 16 comparisons. Performance measures included area under the receiver operating characteristic curve (AUROC), area under precision-recall curve (AUPRC), balanced accuracy, Brier score, expected calibration error with 15 equal-width bins (ECE15), negative log-likelihood, high-confidence errors, and flags per 1000 images at source-validation Youden thresholds. Percentile intervals were estimated from 500 target-set bootstrap replicates, resampling patients where identifiers were available and images otherwise.

Results

Same-label pneumonia transfer produced ensemble AUROCs of 0.699 (95% CI, 0.664-0.732) from Kaggle/Kermany to CheXpert and 0.758 (0.718-0.797) in the reverse direction. Opacity transfer produced AUROCs of 0.824 (0.808-0.841) from RSNA to CheXpert and 0.835 (0.820-0.847) in the reverse direction. ECE15 ranged from 0.053 to 0.533. For Kaggle pneumonia to RSNA opacity, 28.4% (1096/3853) of all images were both incorrect and at least 0.90 confident. On CheXpert opacity, Kaggle- and RSNA-derived thresholds flagged 959.5 and 348.0 images per 1000, respectively.

Conclusion

Model ranking, probability error, confident mistakes, and threshold-based flag volume varied across dataset-defined tasks. These results support reporting complementary measures and checking label provenance when evaluating image models across datasets. They do not establish clinical effectiveness or validate a clinical workflow.

Zitieren

APA

Sakib, S. H., Poppy, S. A., Shaikh, M. H., ., N., Hosan, M. A., Sorna, I. J., & Rahat, S. R. U. I. (2026). Cross-Dataset Reliability of Chest Radiograph Models: A Provenance-Aware Evaluation of Performance and Thresholds. Cureus. https://doi.org/10.7759/cureus.119832

Vancouver

Sakib SH, Poppy SA, Shaikh MH, . N, Hosan MA, Sorna IJ, et al. Cross-Dataset Reliability of Chest Radiograph Models: A Provenance-Aware Evaluation of Performance and Thresholds. Cureus. 2026. doi:10.7759/cureus.119832

BibTeX
@article{Sakib2026,
  author = {Sakib, Sadman Haque and Poppy, Sharmin Akter and Shaikh, Murtaza Hussain and ., Najmuddin and Hosan, Md Anik and Sorna, Irin Jahan and Rahat, Sk Rakib Ul Islam},
  title = {Cross-Dataset Reliability of Chest Radiograph Models: A Provenance-Aware Evaluation of Performance and Thresholds},
  journal = {Cureus},
  year = {2026},
  doi = {10.7759/cureus.119832}
}
Kostenlos starten →