Comparison of PGE2 Gel and Transcervical Foley Single-Balloon Catheter for Induction of Labor in Term Pregnancy: An Open-Label Randomized Controlled Trial
Cureus · 15.11.2026
DOI: 10.7759/cureus.119719 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Cureus, erschienen am 15.11.2026. Verfasst von Supriya Subhi und 3 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben.
Abstract (Originalsprache)
Objective
This study aims to compare the efficacy and safety of transcervical Foley catheter and vaginal prostaglandin E₂ (PGE₂) gel for cervical ripening and induction of labor in women with an unfavorable cervix. Materials and methods: This prospective randomized controlled trial was conducted at a tertiary care center. A total of 86 women requiring induction of labor with an unfavorable cervix were randomized to the Foley catheter induction group or the PGE₂ gel group, with 43 participants in each group. Cervical ripening was assessed using the Bishop’s score before and after induction. Primary outcomes included change in Bishop’s score and individual cervical parameters. Secondary outcomes included the induction-to-active labor interval, induction-to-delivery interval, mode of delivery, failed induction, requirement for oxytocin augmentation, and maternal and fetal adverse outcomes.
Results
Baseline characteristics and pre-induction Bishop’s scores were comparable between groups. Post-induction mean increase in Bishop’s score was significantly greater with Foley catheter induction (5.40 ± 0.23 vs. 3.81 ± 0.29; p = 0.001) compared to PGE2 gel. Foley catheter use resulted in significantly greater improvement in cervical length (1.35 ± 0.12 cm vs. 0.81 ± 0.16 cm; p < 0.01) and cervical dilatation (1.26 ± 0.43 cm vs. 0.95 ± 0.71 cm; p < 0.01). A higher proportion of women achieved a soft cervix following Foley catheter induction (81% vs. 55.8%; p = 0.011). Labor outcomes, mode of delivery, and adverse events were comparable between groups.
Conclusion
Foley catheter induction provides superior cervical ripening with comparable safety and labor outcomes, supporting its use as an effective method for labor induction.
Zitieren
APA
Subhi, S., Jha, S., Bhagat, R., & Pravina, P. (2026). Comparison of PGE2 Gel and Transcervical Foley Single-Balloon Catheter for Induction of Labor in Term Pregnancy: An Open-Label Randomized Controlled Trial. Cureus. https://doi.org/10.7759/cureus.119719
Vancouver
Subhi S, Jha S, Bhagat R, Pravina P. Comparison of PGE2 Gel and Transcervical Foley Single-Balloon Catheter for Induction of Labor in Term Pregnancy: An Open-Label Randomized Controlled Trial. Cureus. 2026. doi:10.7759/cureus.119719
BibTeX
@article{Subhi2026,
author = {Subhi, Supriya and Jha, Sangam and Bhagat, Raveena and Pravina, Pammy},
title = {Comparison of PGE2 Gel and Transcervical Foley Single-Balloon Catheter for Induction of Labor in Term Pregnancy: An Open-Label Randomized Controlled Trial},
journal = {Cureus},
year = {2026},
doi = {10.7759/cureus.119719}
}
EUVIMED