EUVIMEDEUVIMED entdecken
Open Access

Time-Dependent Analysis of Blood Glucose Stability in Sodium Fluoride Versus Plain Blood Collection Tubes

Kuldeep K Gupta, Tabassum Yasmin, Farhat Khan, Priyanka Asia

Cureus · 08.11.2026

DOI: 10.7759/cureus.119320 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cureus, erschienen am 08.11.2026. Verfasst von Kuldeep K Gupta und 3 weiteren Autor:innen. Beteiligte Einrichtung: Biochemistry, Uma Nath Singh Autonomous State Medical College, Jaunpur, Jaunpur, IND. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: Sodium fluoride (NaF) tubes are routinely recommended for blood glucose estimation because of their glycolysis-inhibiting properties. However, NaF inhibits enolase, a downstream glycolytic enzyme, and does not immediately prevent glucose consumption by blood cells. This raises the following questions: How does glucose stability compare between NaF plasma and plain serum over time? Does NaF offer better glucose preservation than plain serum? Does prompt separation of blood cells improve glucose stability? This study aimed to compare glucose stability in NaF plasma and plain serum at different time intervals and assess the effect of prompt cell separation on glucose preservation under routine laboratory conditions. Materials and methods: This prospective observational study included 172 paired blood samples collected simultaneously in NaF and plain serum tubes. Samples were categorized into three groups: Group 1, plasma from NaF tubes; Group 2, serum from plain tubes; and Group 3, serum separated after centrifugation(using LabTop centrifuge at 3000 rpm for 10 minutes) and aliquoted into microcentrifuge tubes. Groups 1 and 2 were analyzed (using clinical chemistry analyzer Bonavera Chem 200, Biogeny Diagnostics Pvt. Ltd., Beacon Group, Surat, India) at

Schlagwörter

Stichwörter der Autor:innen

glucose stabilityplain vialplasma glucose levelspreanalytical variableserum blood glucosesodium fluoride tubes

Autor:innen und Institutionen

  • Biochemistry, Uma Nath Singh Autonomous State Medical College, Jaunpur, Jaunpur, IND.
  • Biochemistry, NKP Salve Institute of Medical Sciences and Research Centre and Lata Mangeshkar Hospital, Nagpur, IND.

Zitieren

APA

Gupta, K. K., Yasmin, T., Khan, F., & Asia, P. (2026). Time-Dependent Analysis of Blood Glucose Stability in Sodium Fluoride Versus Plain Blood Collection Tubes. Cureus. https://doi.org/10.7759/cureus.119320

Vancouver

Gupta KK, Yasmin T, Khan F, Asia P. Time-Dependent Analysis of Blood Glucose Stability in Sodium Fluoride Versus Plain Blood Collection Tubes. Cureus. 2026. doi:10.7759/cureus.119320

BibTeX
@article{Gupta2026,
  author = {Gupta, Kuldeep K and Yasmin, Tabassum and Khan, Farhat and Asia, Priyanka},
  title = {Time-Dependent Analysis of Blood Glucose Stability in Sodium Fluoride Versus Plain Blood Collection Tubes},
  journal = {Cureus},
  year = {2026},
  doi = {10.7759/cureus.119320}
}
Kostenlos starten →