EUVIMEDEUVIMED entdecken
FallberichtOpen Access

Late Infective Endocarditis Involving a Gore HELEX® Atrial Septal Occluder Presenting as a Multiple Sclerosis Pseudo-Flare: A Case Report

Laura Krause, Nicholas Stancil, Adam Morley, Susan Noe

Cureus · 19.07.2026

DOI: 10.7759/cureus.112965 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Cureus, erschienen am 19.07.2026. Verfasst von Laura Krause und 3 weiteren Autor:innen. Beteiligte Einrichtung: Internal Medicine, Dwight D. Eisenhower Army Medical Center, Augusta, USA. Die Arbeit nennt 7 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Atrial septal defects (ASDs) are common congenital heart defects that can be corrected with the placement of minimally invasive occlusion devices. There is a very small risk of perioperative infection associated with these devices following placement. Late endocarditis involving occlusion devices is an exceedingly rare complication of percutaneous occlusion devices. Here we present the case of a female in her 30s who presented with neurologic symptoms typical of her multiple sclerosis flares, but was found to be secondary to late infective endocarditis of an ASD occlusion device requiring surgical excision.

Schlagwörter

Stichwörter der Autor:innen

atrial septal defectscardiac device-related infective endocarditismssa bacteremiapercutaneous atrial septal defect closurestaphylococcus aureus endocarditis

Autor:innen und Institutionen

  • Internal Medicine, Dwight D. Eisenhower Army Medical Center, Augusta, USA.
  • Cardiology, Dwight D. Eisenhower Army Medical Center, Augusta, USA.

Zitieren

APA

Krause, L., Stancil, N., Morley, A., & Noe, S. (2026). Late Infective Endocarditis Involving a Gore HELEX® Atrial Septal Occluder Presenting as a Multiple Sclerosis Pseudo-Flare: A Case Report. Cureus. https://doi.org/10.7759/cureus.112965

Vancouver

Krause L, Stancil N, Morley A, Noe S. Late Infective Endocarditis Involving a Gore HELEX® Atrial Septal Occluder Presenting as a Multiple Sclerosis Pseudo-Flare: A Case Report. Cureus. 2026. doi:10.7759/cureus.112965

BibTeX
@article{Krause2026,
  author = {Krause, Laura and Stancil, Nicholas and Morley, Adam and Noe, Susan},
  title = {Late Infective Endocarditis Involving a Gore HELEX® Atrial Septal Occluder Presenting as a Multiple Sclerosis Pseudo-Flare: A Case Report},
  journal = {Cureus},
  year = {2026},
  doi = {10.7759/cureus.112965}
}