EUVIMEDEUVIMED entdecken
KohortenstudieOpen Access

Three-Dimensional Assessment of Composite Attachment Wear in Clear Aligner Therapy: A Prospective Cohort Study

Zainab Malik, Varun Goyal, Gurkeerat Singh, Raj Kumar Singh, Saba Khan

Cureus · 04.07.2026

DOI: 10.7759/cureus.112065 ↗

Kurz gefasst

Kohortenstudie in der Zeitschrift Cureus, erschienen am 04.07.2026. Verfasst von Zainab Malik und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics and Dentofacial Orthopaedics, Sudha Rustagi College of Dental Sciences and Research, Faridabad, IND. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Clear aligner therapy relies on composite attachments for precise tooth movement; however, wear may compromise force delivery and treatment efficacy. This study quantitatively assessed morphometric changes in the attachment dimensions and volume over six months and explored patterns according to sex, jaw, and tooth position. MATERIALS AND METHODS: This prospective cohort study included 12 adults (aged >18 years) with mild-to-moderate malocclusion, contributing 50 attachments bonded with G-ænial Universal Flo (GC Corporation, Tokyo, Japan) composite material. Intraoral scans were obtained post-attachment bonding (T1) and at six months (T6). Attachments were isolated and analyzed using SOLIDWORKS software (Dassault Systèmes SolidWorks Corp., Waltham, Massachusetts) for changes in width, length, height, and volume. Non-parametric tests and linear mixed models were used to evaluate the wear patterns (significance: p 0.05). CONCLUSIONS: Significant reductions in attachment dimensions and volume were observed over six months, confirming progressive wear during clear aligner therapy. Posterior and mandibular attachments demonstrated greater attrition, highlighting the influence of biomechanical loading and anatomical location. Regular monitoring of attachment integrity and the use of more wear-resistant materials may improve force delivery, treatment efficiency, and clinical predictability.

Schlagwörter

Stichwörter der Autor:innen

attachmentclear alignersin vivolossvolume

Autor:innen und Institutionen

  • Department of Orthodontics and Dentofacial Orthopaedics, Sudha Rustagi College of Dental Sciences and Research, Faridabad, IND.
  • Department of Orthodontics and Dentofacial Orthopaedics, The Regional Institute of Medical Sciences, Imphal, IND.
  • Department of Orthodontics and Dentofacial Orthopaedics, Dr. Ziauddin Ahmed Dental College and Hospital, Aligarh, IND.

Zitieren

APA

Malik, Z., Goyal, V., Singh, G., Singh, R. K., & Khan, S. (2026). Three-Dimensional Assessment of Composite Attachment Wear in Clear Aligner Therapy: A Prospective Cohort Study. Cureus. https://doi.org/10.7759/cureus.112065

Vancouver

Malik Z, Goyal V, Singh G, Singh RK, Khan S. Three-Dimensional Assessment of Composite Attachment Wear in Clear Aligner Therapy: A Prospective Cohort Study. Cureus. 2026. doi:10.7759/cureus.112065

BibTeX
@article{Malik2026,
  author = {Malik, Zainab and Goyal, Varun and Singh, Gurkeerat and Singh, Raj Kumar and Khan, Saba},
  title = {Three-Dimensional Assessment of Composite Attachment Wear in Clear Aligner Therapy: A Prospective Cohort Study},
  journal = {Cureus},
  year = {2026},
  doi = {10.7759/cureus.112065}
}
Kostenlos starten →