Accuracy of a Digital Intraoral Scanner in Recording Occlusal Contact Points in Patients with Natural Dentition Compared to 8-µm Articulating Paper: A Cross-Sectional In-Vivo Study
Cureus · 29.05.2026
DOI: 10.7759/cureus.109859 ↗Kurz gefasst
Querschnittstudie in der Zeitschrift Cureus, erschienen am 29.05.2026. Verfasst von Tolay Almahdi Altounsi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Fixed Prosthodontics, Faculty of Dentistry, University of Damascus, Damascus, SYR. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Recent developments in digital dentistry have introduced intraoral scanners (IOSs) as potential alternatives to conventional methods for recording occlusal contact. However, clinical evidence comparing their diagnostic accuracy against the gold standard (8-μm articulating paper) remains limited, particularly regarding tooth-type-specific performance.
Objective
This cross-sectional comparative study evaluated the accuracy of the Cameo Elegant 3 intraoral scanner (IOS) for static occlusion contact detection compared to 8-μm articulating paper and determined whether tooth type (premolars vs. molars) influences contact point accuracy. Materials and methods Thirty-five patients (11 men, 24 women; aged 21-29 years) underwent occlusal assessment during a single visit. Occlusal contacts were marked with 8-μm Bausch articulating paper. The marked contact points were then immediately scanned using the Cameo Elegant 3 IOS. Digital scans of mandibular/maxillary arches and bite registration were obtained. Digital models were superimposed in Exocad software to identify matching and non-matching contact points (n=412 contacts across 140 posterior teeth). Point-level analysis was performed using confusion matrices and Cohen's kappa, while tooth-level data were analyzed using the Wilcoxon signed-rank test. Premolar-molar differences were assessed via chi-square/Fisher's exact tests, Mann-Whitney U, Spearman's correlation, and ROC curves using SPSS v27 (α=0.05).
Results
The scanner showed high sensitivity (90.4%, 95% CI: 87.4-93.0) but poor specificity (14.3%), with significant under-recording vs. articulating paper (p
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Fixed Prosthodontics, Faculty of Dentistry, University of Damascus, Damascus, SYR.
- Department of Orthodontics, Faculty of Dentistry, University of Damascus, Damascus, SYR.
Zitieren
APA
Almahdi Altounsi, T., Morad, M. L., & Hajeer, M. Y. (2026). Accuracy of a Digital Intraoral Scanner in Recording Occlusal Contact Points in Patients with Natural Dentition Compared to 8-µm Articulating Paper: A Cross-Sectional In-Vivo Study. Cureus. https://doi.org/10.7759/cureus.109859
Vancouver
Almahdi Altounsi T, Morad ML, Hajeer MY. Accuracy of a Digital Intraoral Scanner in Recording Occlusal Contact Points in Patients with Natural Dentition Compared to 8-µm Articulating Paper: A Cross-Sectional In-Vivo Study. Cureus. 2026. doi:10.7759/cureus.109859
BibTeX
@article{AlmahdiAltounsi2026,
author = {Almahdi Altounsi, Tolay and Morad, Mohammad Luai and Hajeer, Mohammad Y},
title = {Accuracy of a Digital Intraoral Scanner in Recording Occlusal Contact Points in Patients with Natural Dentition Compared to 8-µm Articulating Paper: A Cross-Sectional In-Vivo Study},
journal = {Cureus},
year = {2026},
doi = {10.7759/cureus.109859}
}
EUVIMED