ErNP@SiO2-ICG NIR Probes Enhance Thoracoscopy for Diagnosing Malignant Pleural Effusion in Internal Medicine
Clinical Laboratory · 2026 · 72 (07/2026)
DOI: 10.7754/clin.lab.2025.250827 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Laboratory, 2026. Verfasst von Chuchu Xu und 10 weiteren Autor:innen. Hauptthemen laut MEDLINE: Pleural Effusion, Malignant, Thoracoscopy, Silicon Dioxide, Fluorescent Dyes.
Abstract (Originalsprache)
BACKGROUND: The study investigated the efficacy of internal thoracoscopy combined with multi-site biopsy and erbium nanoparticle-containing silica-indocyanine green composite covered (ErNP@SiO2-ICG) near-infrared fluorescent probe technology in the diagnosis of malignant pleural effusion. METHODS: Internal medicine: This procedure was conducted on 90 patients with pleural effusion at the Department of Respiratory Medicine of the Second People's Hospital of Hefei City between January 2021 and October 2024. The procedure included pleural biopsy, pleural fluid staining, near-infrared fluorescence biopsy system analysis, and cytology of pleural effusion. RESULTS: Out of the 90 patients who had thoracoscopies, 20 had an unclear diagnosis, 35 had benign lesions, and 35 had malignant lesions. Thoracoscopy had a positive predictive value of 75.80%, a negative predictive value of 73.00%, a sensitivity of 71.40%, a specificity of 77.10%, and a concordance rate of 74.29% matched with pathological diagnosis for malignant lesions. The positive predictive value for the diagnosis of malignant pleural effusion increased to 80.00% when paired with an ErNP@SiO2-ICG near-infrared fluorescent probe. The negative predictive value was 82.90%, the degree of certainty was 82.40%, the specificity was 80.60%, and there was good concordance with the final pathological results (Kappa value of 0.629, p < 0.001). CONCLUSIONS: Internal thoracoscopy has a high detection rate and accuracy in the diagnosis of pleural effusion, and when combined with the ErNP@SiO₂-ICG near-infrared fluorescent probe technology, it improves the diagnostic accuracy of malignant pleural effusion.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Zitieren
APA
Xu, C., Wang, X., Yin, X., Zhou, L., Liu, X., Du, F., Jiang, Y., Zhang, Y., Su, D., Wang, Y., & Wang, X. (2026). ErNP@SiO2-ICG NIR Probes Enhance Thoracoscopy for Diagnosing Malignant Pleural Effusion in Internal Medicine. Clinical Laboratory, 72(07/2026). https://doi.org/10.7754/clin.lab.2025.250827
Vancouver
Xu C, Wang X, Yin X, Zhou L, Liu X, Du F, et al. ErNP@SiO2-ICG NIR Probes Enhance Thoracoscopy for Diagnosing Malignant Pleural Effusion in Internal Medicine. Clinical Laboratory. 2026;72(07/2026). doi:10.7754/clin.lab.2025.250827
BibTeX
@article{Xu2026,
author = {Xu, Chuchu and Wang, Xi and Yin, Xiaona and Zhou, Lijuan and Liu, Xiaoyue and Du, Fangbin and Jiang, Yinling and Zhang, Yadi and Su, Dongmei and Wang, Yongsheng and Wang, Xiaoqiong},
title = {ErNP@SiO2-ICG NIR Probes Enhance Thoracoscopy for Diagnosing Malignant Pleural Effusion in Internal Medicine},
journal = {Clinical Laboratory},
year = {2026},
volume = {72},
number = {07/2026},
doi = {10.7754/clin.lab.2025.250827}
}
EUVIMED