Comparison of Anti-dsDNA Evaluation with 20x and 40x Objectives in Automated Systems to Expert Agreement

M A Durmus, B Oncel

Clinical Laboratory · 2026

DOI: 10.7754/clin.lab.2025.250417 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Laboratory, 2026. Verfasst von M A Durmus und 1 weiteren Autor:innen. Hauptthemen laut MEDLINE: DNA, Antibodies, Antinuclear.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: In this study, we investigated the effect of using a 40x objective instead of the recommended 20x objective in the computer-assisted automated evaluation of anti-dsDNA antibodies using the Crithidia luciliae indirect immunofluorescence (CLIF) test. By using a 40x objective, we aimed to increase the accuracy and specificity of the CLIF test by improving image clarity and enabling easier interpretation by the expert physician. METHODS: Anti-dsDNA tests of 156 positive and 40 negative samples were evaluated using the automated EURO-Pattern system at 20x and 40x magnifications. The results were compared with the assessments of experienced physicians. Statistical analysis included chi-squared and kappa agreement tests. Sensitivity, specificity, and accuracy metrics were calculated for both objectives. RESULTS: When evaluated with the 20x objective, the system achieved a sensitivity of 100%, specificity of 29.85%, and accuracy of 50.26%, with a kappa coefficient of 0.199 (95% CI: 0.129 - 0.267). With the 40x objective, sensitivity was 94.55%, specificity was 90.30%, and accuracy was 91.53%, with a kappa coefficient of 0.805 (95% CI: 0.714 - 0.895). The agreement between the automated system and the expert evaluations significantly improved with the 40x objective. CONCLUSIONS: Using a 40x microscope objective enhances the compatibility between automated systems and expert evaluations, providing clearer and larger images. This adjustment reduces false positives, increases accuracy, and facilitates decision-making for specialists, supporting the adoption of 40x objectives for routine laboratory use.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DNAAntibodies, AntinuclearHumansSensitivity and SpecificityFluorescent Antibody Technique, IndirectReproducibility of ResultsCrithidiaAutomation, LaboratoryAnimals

Substanzen

DNAAntibodies, Antinuclear

Zitieren

APA

Durmus, M. A., & Oncel, B. (2026). Comparison of Anti-dsDNA Evaluation with 20x and 40x Objectives in Automated Systems to Expert Agreement. Clinical Laboratory. https://doi.org/10.7754/clin.lab.2025.250417

Vancouver

Durmus MA, Oncel B. Comparison of Anti-dsDNA Evaluation with 20x and 40x Objectives in Automated Systems to Expert Agreement. Clinical Laboratory. 2026. doi:10.7754/clin.lab.2025.250417

BibTeX
@article{Durmus2026,
  author = {Durmus, M A and Oncel, B},
  title = {Comparison of Anti-dsDNA Evaluation with 20x and 40x Objectives in Automated Systems to Expert Agreement},
  journal = {Clinical Laboratory},
  year = {2026},
  doi = {10.7754/clin.lab.2025.250417}
}
Kostenlos starten →