Comparison of Cerebrospinal Fluid Cellular Analysis by Optical Microscopy and Sysmex XN 9000

Xiu-Qin Ren, Xi Jiang, Ying-Qi Pi, Zhi-Kun Wu, Hong-Bo Jiang, Hua-Cheng Wang

Clinical Laboratory · 2023

DOI: 10.7754/clin.lab.2023.230403 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Laboratory, 2023. Verfasst von Xiu-Qin Ren und 5 weiteren Autor:innen. Hauptthemen laut MEDLINE: Microscopy, Body Fluids.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: This study was designed to compare the body fluid module of Sysmex XN9000 (XN-BF) with optical microscopy (OM) for cerebrospinal fluid (CSF) analysis after two-step cell slide centrifuge (TSCSC), defining the best procedure for CSF optical microscopy analysis. METHODS: Items of RBC, WBC enumeration and differentiation were observed. The cell count and morphologic evaluation of the cellular composition by OM was carried out both with and without two-step cell slide centrifuge (TSCSC) and were compared the data with XN-BF. RESULTS: There were 69.98 ± 4.94 RBC and 36.98 ± 3.39 WBC in one OSCSC microscopic field whereas there were 96.35 ± 5.41 RBC and 66.15 ± 4.85 WBC in one TSCSC microscopic field in the same sample (*200). There was a statistical difference between those two methods (p = 0.000). Excellent correlation was found between total cell count with both OM and XN-BF. The R2 value for RBC and WBC counts were 0.99 and 0.96, respectively. For WBC differential, the R2 values were 0.98 for PMN and 0.70 for MN. Correlation of MN was poorer than PMN. As far as the tumor cell, phagocyte, and plasma cell with high fluorescence were concerned, OM were not consistent with XN-BF. CONCLUSIONS: The TSCSC procedure contributes to the separation of cells and other ingredients. XN-BF displays excellent performance at RBC and WBC cell count except for mononuclear cells, tumor cells, phagocytes, and leukemia cells. which makes it just a practical alternative to total cell (WBC, RBC) count for CSF samples. Detailed morphologic workup of CSF samples is mandated in all cases with meningoencephalitis, elevated cell count, sub-arachnoid hemorrhage and meningeal carcinomatosis, the TSCSC procedure is recommended.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicroscopyBody FluidsHumansLeukocyte CountLeukocytesCell DifferentiationCerebrospinal FluidReproducibility of Results

Zitieren

APA

Ren, X. Q., Jiang, X., Pi, Y. Q., Wu, Z. K., Jiang, H. B., & Wang, H. C. (2023). Comparison of Cerebrospinal Fluid Cellular Analysis by Optical Microscopy and Sysmex XN 9000. Clinical Laboratory. https://doi.org/10.7754/clin.lab.2023.230403

Vancouver

Ren XQ, Jiang X, Pi YQ, Wu ZK, Jiang HB, Wang HC. Comparison of Cerebrospinal Fluid Cellular Analysis by Optical Microscopy and Sysmex XN 9000. Clinical Laboratory. 2023. doi:10.7754/clin.lab.2023.230403

BibTeX
@article{Ren2023,
  author = {Ren, Xiu-Qin and Jiang, Xi and Pi, Ying-Qi and Wu, Zhi-Kun and Jiang, Hong-Bo and Wang, Hua-Cheng},
  title = {Comparison of Cerebrospinal Fluid Cellular Analysis by Optical Microscopy and Sysmex XN 9000},
  journal = {Clinical Laboratory},
  year = {2023},
  doi = {10.7754/clin.lab.2023.230403}
}
Kostenlos starten →