A Rare Case of Falsely Elevated High-Sensitivity Cardiac Troponin T due to Antibody Interference and a Literature Review

Fu Cheng, Jie Chen, Bing L Wu, Xing Yang, Yuan S Huang

Clinical Laboratory · 2023

DOI: 10.7754/clin.lab.2023.230230 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Clinical Laboratory, 2023. Verfasst von Fu Cheng und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Troponin T, Antibodies. Die Arbeit wurde bisher 2-mal zitiert (Crossref).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: This study aimed to demonstrate potential measures to discern interference and establish an algorithm for identifying interference in an hs-cTnT assay with a clinical discrepancy. METHODS: Laboratory error and disease factors were first excluded. Then, a serial dilution test, polyethylene glycol (PEG) precipitation, and heterophile antibody blocking reagents (HBRs) were performed to confirm the interference substance. In addition, high-speed centrifugation and western blot were tried. RESULTS: The sample diluted linearly (R2 = 0.9966). However, there was a dramatic reduction in the concentration of hs-cTnT concentration to a normal level after both PEG precipitation and HBR1 treatment. The results were inconclusive in high-speed centrifugation and western blot assay. CONCLUSIONS: This study elucidated a heterophile antibody interference in measurement of hs-cTnT alone on a Roche analyzer.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Troponin TAntibodiesHumansIndicators and ReagentsBlotting, WesternBiomarkers

Substanzen

Troponin TAntibodiesIndicators and ReagentsBiomarkers

Zitieren

APA

Cheng, F., Chen, J., Wu, B. L., Yang, X., & Huang, Y. S. (2023). A Rare Case of Falsely Elevated High-Sensitivity Cardiac Troponin T due to Antibody Interference and a Literature Review. Clinical Laboratory. https://doi.org/10.7754/clin.lab.2023.230230

Vancouver

Cheng F, Chen J, Wu BL, Yang X, Huang YS. A Rare Case of Falsely Elevated High-Sensitivity Cardiac Troponin T due to Antibody Interference and a Literature Review. Clinical Laboratory. 2023. doi:10.7754/clin.lab.2023.230230

BibTeX
@article{Cheng2023,
  author = {Cheng, Fu and Chen, Jie and Wu, Bing L and Yang, Xing and Huang, Yuan S},
  title = {A Rare Case of Falsely Elevated High-Sensitivity Cardiac Troponin T due to Antibody Interference and a Literature Review},
  journal = {Clinical Laboratory},
  year = {2023},
  doi = {10.7754/clin.lab.2023.230230}
}
Kostenlos starten →