EUVIMEDEUVIMED entdecken
Crossref

A Single-Tube 21-Color Multiparameter Flow Cytometry Improve the Sensitivity of B-ALL MRD Analysis

Qingchen Wang, Ran You, Linzi Miao, Yao Lu, Yan Gong, Xu Wu, Huizheng Ge, Shuzhen Zhai, Chenxue Qu

Clinical Laboratory · 2023

DOI: 10.7754/clin.lab.2023.230226 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Laboratory, 2023. Verfasst von Qingchen Wang und 8 weiteren Autor:innen. Hauptthemen laut MEDLINE: Precursor B-Cell Lymphoblastic Leukemia-Lymphoma, Precursor Cell Lymphoblastic Leukemia-Lymphoma.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Detection of minimal residual disease (MRD) by multiparameter flow cytometry (MFC) is a well-established risk stratification factor and therapeutic modification strategy in B acute lymphoblastic leukemia (B-ALL). However, current 8 color (8c)-MFC for MRD detection had the sensitivity of 0.01% with false negative or positive. Hence, a more sensitive and applicable MFC-MRD method is urgently needed. The aim of this study is to establish a single-tube 21c-MFC method to detect B-ALL MRD, evaluate its performance, and to investigate its preliminary clinical application. METHODS: We selected 21 markers to establish a single-tube 21c-MFC method. The repeatability and sensitivity of this method was validated by adding Nalm-6 cells to normal bone marrow. Samples from control group (n = 6), B-ALL group (n = 7) and complete remission (CR) group (n = 26) were detected by 21c- and 8c-MFC separately. The expression characteristics of these markers was analyzed in control and B-ALL group, and the consistency of 21c- and 8c-MFC in detecting MRD was compared. RESULTS: Repeatability of this method was 1.91% of CV and sensitivity was up to 0.005%. In control group, the expression of CD81, CD97, and CD200 gradually decreased and CD44, HLA-DR, CD73, and CD72 gradually increased with the maturation of normal B cells. In B-ALL group, CD73stro, CD81low, CD44stro, CD123stro, and CD58stro showed high-frequency expression. The consistency rate of 21c- and 8c-MFC in detecting MRD was 96%. CONCLUSIONS: A single-tube 21c-MFC method was established for MRD detection in B-ALL and had higher sensitivity than the 8c-MFC method.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Precursor B-Cell Lymphoblastic Leukemia-LymphomaPrecursor Cell Lymphoblastic Leukemia-LymphomaHumansFlow CytometryNeoplasm, Residual

Zitieren

APA

Wang, Q., You, R., Miao, L., Lu, Y., Gong, Y., Wu, X., Ge, H., Zhai, S., & Qu, C. (2023). A Single-Tube 21-Color Multiparameter Flow Cytometry Improve the Sensitivity of B-ALL MRD Analysis. Clinical Laboratory. https://doi.org/10.7754/clin.lab.2023.230226

Vancouver

Wang Q, You R, Miao L, Lu Y, Gong Y, Wu X, et al. A Single-Tube 21-Color Multiparameter Flow Cytometry Improve the Sensitivity of B-ALL MRD Analysis. Clinical Laboratory. 2023. doi:10.7754/clin.lab.2023.230226

BibTeX
@article{Wang2023,
  author = {Wang, Qingchen and You, Ran and Miao, Linzi and Lu, Yao and Gong, Yan and Wu, Xu and Ge, Huizheng and Zhai, Shuzhen and Qu, Chenxue},
  title = {A Single-Tube 21-Color Multiparameter Flow Cytometry Improve the Sensitivity of B-ALL MRD Analysis},
  journal = {Clinical Laboratory},
  year = {2023},
  doi = {10.7754/clin.lab.2023.230226}
}
Kostenlos starten →