EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 3.0

Effect of antagonist activation on agonist muscle activity during strength training

Wollner Materko, Wilson Lobato Souza, Caio Cesar dos Reis Façanha, Sávio Andrei Medeiros Miranda, Thiago Henrique Lobato Bezerra, Gizelly Coelho Guedes, Dilson Rodrigues Belfort

Journal of Physical Education and Sport · 30.11.2024 · 24 (11) · 1986-1991

DOI: 10.7752/jpes.2024.11296 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Physical Education and Sport, online erschienen am 30.11.2024. Verfasst von Wollner Materko und 6 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Strength training, essential for fitness and rehabilitation, relies on the coordinated action of agonist and antagonist muscles. The agonist muscle is responsible for the primary movement, while the antagonist muscle is crucial for stabilization, controlling movement speed, and injury prevention. Recent research has investigated the advantages of including antagonist muscle activation in training programs, which has led to the creation of MAA training methods. This study compares the median frequency (Fmed) values of the electromyography (EMG) signal in the agonist muscle during agonist/antagonist (MAA) and traditional (MT) strength training protocols in experienced male athletes. Materials and methods. This cross-sectional study involved 12 volunteers aged 18–35 years. On the first day, each volunteer's maximum load for 10 repetitions (10RM) was determined for the extensor chair, flexor table, biceps curl, and triceps curl exercises. On the second day, participants were divided into two groups. One group performed a series of MT first, followed by a series of MAA two hours later. The other group started with MAA and then performed the MT series after two hours. Finally, a comparison between the extensor chair and biceps curl exercises was performed using the Student's ttest for dependent samples. All procedures assumed α = 0.05 for statistical significance. All data were processed in Matlab version 2020.b (The MathWorks, USA).

Results

The Fmed values for the extensor chair test at a 10RM load (101.6 ± 20.2 kg) were 78.1 ± 4.3 Hz with MT and 79.1 ± 3.4 Hz with MAA, demonstrating no significant difference (p = 0.856). For the biceps curl test at a 10RM load (27.5 ± 5.1 kg), the Fmed values were 75.6 ± 0.96 Hz with MT and 77.0 ± 3.1 Hz with MAA, also showing no significant difference (p = 0.640).

Conclusion

Assessment of Fmed revealed no significant differences between MAA and MT in upper and lower limb exercises among men with strength training experience.

Zitieren

APA

Materko, W., Souza, W. L., Façanha, C. C. D. R., Miranda, S. A. M., Bezerra, T. H. L., Guedes, G. C., & Belfort, D. R. (2024). Effect of antagonist activation on agonist muscle activity during strength training. Journal of Physical Education and Sport, 24(11), 1986-1991. https://doi.org/10.7752/jpes.2024.11296

Vancouver

Materko W, Souza WL, Façanha CCDR, Miranda SAM, Bezerra THL, Guedes GC, et al. Effect of antagonist activation on agonist muscle activity during strength training. Journal of Physical Education and Sport. 2024;24(11):1986-1991. doi:10.7752/jpes.2024.11296

BibTeX
@article{Materko2024,
  author = {Materko, Wollner and Souza, Wilson Lobato and Façanha, Caio Cesar dos Reis and Miranda, Sávio Andrei Medeiros and Bezerra, Thiago Henrique Lobato and Guedes, Gizelly Coelho and Belfort, Dilson Rodrigues},
  title = {Effect of antagonist activation on agonist muscle activity during strength training},
  journal = {Journal of Physical Education and Sport},
  year = {2024},
  volume = {24},
  number = {11},
  pages = {1986--1991},
  doi = {10.7752/jpes.2024.11296}
}
Kostenlos starten →