EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Evaluation of Fire-Extinguishing Performance of HFC-125a Gas Hydrate Fire-Extinguishing Projectiles Based on Discharge Method

Sugil Choi, Sinwoo Kim, Seunggeun Park, Donggun Nam

Fire Science and Engineering · 31.10.2026 · 40 (5) · 30-41

DOI: 10.7731/kifse.ce804e5f ↗

Kurz gefasst

Fachartikel in der Zeitschrift Fire Science and Engineering, erschienen am 31.10.2026. Verfasst von Sugil Choi und 3 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Fire Agency.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study evaluated the effects of fire class and discharge method on the fire-extinguishing characteristics of HFC-125a gas hydrate fire-extinguishing projectiles. Direct and indirect discharge tests were conducted for Class A and Class B liquid fires using a Grade 4 fire test model based on the “Technical Standards for Type Approval and Product Inspection of Automatic Gas and Powder Fire-Extinguishing Systems.” Fire temperature, oxygen concentration, extinguishing time, and reignition were analyzed. In the Class A Grade 4 direct-discharge test, visible flame was extinguished within approximately 1 s after discharge, and the temperature directly above the fire source decreased from approximately 780 ℃ to 105 ℃ without reignition. In the Class A indirect-discharge test, visible flame was extinguished at 482 s. In the Class B Grade 4 direct-discharge test, fuel scattering and rapid flame spread occurred. Additionally, sustained flaming was observed in the Supplementary Grade 3 test, thus indicating the limited extinguishing applicability of direct discharge. By contrast, indirect discharge extinguished Class B fire at 430 s, thereby reducing the extinguishing time by 153 s—or approximately 26.2%—compared with that (583 s) under natural burning conditions. Therefore, direct discharge is considered suitable for Class A wood fires, whereas indirect discharge is more appropriate for Class B liquid fires.

Förderung

  • National Fire Agency

Zitieren

APA

Choi, S., Kim, S., Park, S., & Nam, D. (2026). Evaluation of Fire-Extinguishing Performance of HFC-125a Gas Hydrate Fire-Extinguishing Projectiles Based on Discharge Method. Fire Science and Engineering, 40(5), 30-41. https://doi.org/10.7731/kifse.ce804e5f

Vancouver

Choi S, Kim S, Park S, Nam D. Evaluation of Fire-Extinguishing Performance of HFC-125a Gas Hydrate Fire-Extinguishing Projectiles Based on Discharge Method. Fire Science and Engineering. 2026;40(5):30-41. doi:10.7731/kifse.ce804e5f

BibTeX
@article{Choi2026,
  author = {Choi, Sugil and Kim, Sinwoo and Park, Seunggeun and Nam, Donggun},
  title = {Evaluation of Fire-Extinguishing Performance of HFC-125a Gas Hydrate Fire-Extinguishing Projectiles Based on Discharge Method},
  journal = {Fire Science and Engineering},
  year = {2026},
  volume = {40},
  number = {5},
  pages = {30--41},
  doi = {10.7731/kifse.ce804e5f}
}
Kostenlos starten →