Application of Experimental Smoke-Detector Database to Fire Dynamics Simulator Input Parameters for Performance-Based Design
International Journal of Fire Science and Engineering · 30.09.2026 · 40 (3) · 1-13
DOI: 10.7731/kifse.cdd3f182 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Fire Science and Engineering, erschienen am 30.09.2026. Verfasst von Hyo-Yeon Jang und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Reliable prediction of smoke-detector activation time is essential for assessing the required safe egress time (RSET) in performance-based designs. No new experiments were conducted because the purpose of this study was to compile and reorganize previously reported experimental data to develop a procedure for selecting input parameters for a Fire Dynamics Simulator (FDS) smoke detector. Previously reported measurements of input parameters for the Heskestad and Cleary smoke-detector models in FDS were compiled and reanalyzed, and a user-friendly selection procedure was developed using the detector and combustible information. The database—obtained using a fire-detector evaluator—included parameters governing the time lag measured for specific detectors as well as activation obscuration per meter (OPM) measurements for an ionization detector and photoelectric detectors exposed to smoke from filter paper, liquid fuels, and polymers. For filter paper, the mean activation OPM of the photoelectric detectors was 58.7% lower than that of the ionization detector (16.17 and 39.17 %/m). For kerosene smoke, the corresponding photoelectric mean was 127.1% higher (37.15 and 16.36 %/m). Among photoelectric detectors from nine manufacturers, the mean activation OPM for toluene was 28.8% higher than that for heptane. For polymer smoke tested using detectors from three manufacturers, the value for polystyrene was 72.2% higher than that for polyethylene. The activation OPM varied by detector type, combustible, and manufacturer. Complete measured parameter sets should be used when available. Otherwise, the mean OPM for the combustible may be used as the reference input, with the standard deviation defining the sensitivity conditions, while representative parameters governing the time lag are selected based on detector type and expected smoke color. When the target combustible is absent from the database, representative parameters can be selected based on detector type and smoke color. The soot yield and mass-specific extinction coefficient must be specified for each design fire scenario. This study contributes to the literature by consolidating measurements into a user-friendly procedure for selecting FDS smoke-detector inputs, thus enabling the predicted activation time to serve as the RSET’s detection-time component.
Zitieren
APA
Jang, H., Han, H., Hwang, C., & Klein, B. (2026). Application of Experimental Smoke-Detector Database to Fire Dynamics Simulator Input Parameters for Performance-Based Design. International Journal of Fire Science and Engineering, 40(3), 1-13. https://doi.org/10.7731/kifse.cdd3f182
Vancouver
Jang H, Han H, Hwang C, Klein B. Application of Experimental Smoke-Detector Database to Fire Dynamics Simulator Input Parameters for Performance-Based Design. International Journal of Fire Science and Engineering. 2026;40(3):1-13. doi:10.7731/kifse.cdd3f182
BibTeX
@article{Jang2026,
author = {Jang, Hyo-Yeon and Han, Ho-Sik and Hwang, Cheol-Hong and Klein, Bryan},
title = {Application of Experimental Smoke-Detector Database to Fire Dynamics Simulator Input Parameters for Performance-Based Design},
journal = {International Journal of Fire Science and Engineering},
year = {2026},
volume = {40},
number = {3},
pages = {1--13},
doi = {10.7731/kifse.cdd3f182}
}
EUVIMED