EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Proposal of Performance and Design Requirements for Sprinklers by Protection Zone Based on NFPA 13

Jihyun Kwark

International Journal of Fire Science and Engineering · 30.09.2026 · 40 (3) · 14-31

DOI: 10.7731/kifse.a929c95a ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Fire Science and Engineering, erschienen am 30.09.2026. Verfasst von Jihyun Kwark. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Domestic sprinkler standards are primarily organized according to system type and installation requirements. However, similar criteria are still applied to many protected areas despite substantial differences in combustible characteristics, fire load, fire growth, shielding, evacuation vulnerability, and fire-service accessibility. This study reviews and compares studies and codes, aiming to propose risk-informed sprinkler performance and design requirements for six representative protection zones: single-family homes, parking facilities, storage warehouses, underground spaces, multi-use facilities, and high-rise buildings. NFPA 13 (2025) and NFPA 13D (2025) were selected because they connect occupancy hazard classification with discharge density, hydraulic design operating area, sprinkler coverage, response characteristics, K-factor, and listing limitations. A common procedure was applied: identification of actual use and combustibles, assignment of the basic hazard classification, definition of the performance objective, selection of design variables, application of zone-specific modifiers, and project-level verification. International standards [N], Korean standards [K], literature or test evidence [L], and author proposals [P] were distinguished. The review indicates that residential systems should prioritize early activation and tenability; parking facilities should be evaluated separately for conventional parking, mechanical parking, and electric-vehicle charging; storage protection should follow commodity, packaging, storage height, rack arrangement, and listed protection schemes; underground and multi-use spaces should combine early fire control with smoke management and egress protection; and high-rise buildings should retain occupancy-based hazard classification while adding pressure zoning, water-supply duration, emergency power, and system-reliability requirements. Because no full-scale tests, hydraulic calculations, or fire simulations were performed, the proposed values are preliminary design-review criteria rather than validated project-specific values. The results provide a structured basis for differentiating domestic sprinkler requirements according to fire risk and performance objectives.

Zitieren

APA

Kwark, J. (2026). Proposal of Performance and Design Requirements for Sprinklers by Protection Zone Based on NFPA 13. International Journal of Fire Science and Engineering, 40(3), 14-31. https://doi.org/10.7731/kifse.a929c95a

Vancouver

Kwark J. Proposal of Performance and Design Requirements for Sprinklers by Protection Zone Based on NFPA 13. International Journal of Fire Science and Engineering. 2026;40(3):14-31. doi:10.7731/kifse.a929c95a

BibTeX
@article{Kwark2026,
  author = {Kwark, Jihyun},
  title = {Proposal of Performance and Design Requirements for Sprinklers by Protection Zone Based on NFPA 13},
  journal = {International Journal of Fire Science and Engineering},
  year = {2026},
  volume = {40},
  number = {3},
  pages = {14--31},
  doi = {10.7731/kifse.a929c95a}
}
Kostenlos starten →