EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Sensitization potential of chemical constituents in earphone materials in high-risk populations: a multicenter patch test study

Dihui Lai, Shaowei Cheng, Haiyang Yu, Jianchun Hao, Xiaodi Huang, Saqila He, Yee Jor Choi, Jia Shen, Yumei Wu, Cuihong Lian, Chunlei Huang

PeerJ · 17.11.2026 · 14 · e21926

DOI: 10.7717/peerj.21926 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PeerJ, online erschienen am 17.11.2026. Verfasst von Dihui Lai und 10 weiteren Autor:innen. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Earphone-related allergic contact dermatitis is increasingly reported, yet the sensitization potential of constituent materials remains poorly characterized.

Objectives

To evaluate the allergenic potential of earphone raw materials in a high-risk allergic population using standardized patch testing.

Methods

This two-stage, multicenter prospective study enrolled 261 adults with allergic histories between November 2022 and April 2024 across four regions in China. Stage I patch tested 52 solid materials ( e.g. , paint, adhesive, and ear cap films) in 61 subjects; Stage II tested 28 liquid substances in 200 subjects. Reading was performed according to the International Contact Dermatitis Research Group (ICDRG) criteria.

Results

In Stage I, 66.67% of participants showed ≥ 1 positive allergic reaction to solid earphone raw materials, with adhesives demonstrating the highest per-patch positive allergic reaction rate (7.03%). The overall per-patch positive allergic reaction rate for solid materials was 5.51% (95% CI [4.74–6.38]), significantly lower than that of the Baseline Standard Series (9.50%; 95% CI [7.90–11.30]; P < 0.0001). In Stage II, 15.52% of participants had at least one positive allergic reaction to liquid earphone raw materials, with hexadecamethylcyclooctasiloxane (D8) at 0.01% concentration showing the highest per-patch positive allergic reaction rate (3.45%). The overall per-patch positive allergic reaction rate for liquid materials was 1.13% (95% CI [0.97–1.31]), significantly lower than that of the Baseline Standard Series (14.94%; 95% CI [13.30–16.71]; P < 0.0001).

Conclusion

Earphone raw materials contain potential sensitizers under patch test conditions in allergic individuals, with adhesives and acrylate monomers representing candidate allergens requiring further clinical validation.

Zitieren

APA

Lai, D., Cheng, S., Yu, H., Hao, J., Huang, X., He, S., Choi, Y. J., Shen, J., Wu, Y., Lian, C., & Huang, C. (2026). Sensitization potential of chemical constituents in earphone materials in high-risk populations: a multicenter patch test study. PeerJ, 14, e21926. https://doi.org/10.7717/peerj.21926

Vancouver

Lai D, Cheng S, Yu H, Hao J, Huang X, He S, et al. Sensitization potential of chemical constituents in earphone materials in high-risk populations: a multicenter patch test study. PeerJ. 2026;14:e21926. doi:10.7717/peerj.21926

BibTeX
@article{Lai2026,
  author = {Lai, Dihui and Cheng, Shaowei and Yu, Haiyang and Hao, Jianchun and Huang, Xiaodi and He, Saqila and Choi, Yee Jor and Shen, Jia and Wu, Yumei and Lian, Cuihong and Huang, Chunlei},
  title = {Sensitization potential of chemical constituents in earphone materials in high-risk populations: a multicenter patch test study},
  journal = {PeerJ},
  year = {2026},
  volume = {14},
  pages = {e21926},
  doi = {10.7717/peerj.21926}
}
Kostenlos starten →