Reliability of a functional electromechanical dynamometer for a bilateral standing press exercise at intensities of 30% and 60% of isometric peak force in trained women
PeerJ · 2026
DOI: 10.7717/peerj.21777 ↗Kurz gefasst
Fachartikel in der Zeitschrift PeerJ, 2026. Verfasst von Claudio Cifuentes-Zapata und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Education and Sport, Faculty of Sport Sciences, University of Granada, Granada, Spain. Hauptthemen laut MEDLINE: Muscle Strength, Muscle Strength Dynamometer, Isometric Contraction, Exercise. Die Arbeit nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Determining the reliability of exercise instruments and protocols in the fields of health and sports performance is of great interest due to their close relationship with monitoring and decision-making in athletes. Studies in trained women are limited, and more evidence is needed on performance variables and the reliability of exercise protocols.
Objective
This study aimed to evaluate the reliability of an exercise protocol for determining mean muscle strength, mean velocity, and mean power during the bilateral standing press (BSP) in trained women.
Methods
Sixteen trained women (age = 20.0 ± 2.30 years; body mass = 67.63 ± 6.68 kg; height = 1.65 ± 0.06 m) participated in this repeated-measures study. Absolute reliability was assessed using the coefficient of variation (CV), and relative reliability was assessed using the intraclass correlation coefficient (ICC) for a bilateral standing press (BSP) exercise protocol performed at intensities of 30% and 60% of isometric peak force (IPF).
Results
Mean muscle strength showed acceptable absolute reliability and extremely high relative reliability at both 30% IPF (CV = 6.51%; ICC = 0.94) and 60% IPF (CV = 5.03%; ICC = 0.97). Mean velocity showed extremely high relative reliability at 60% IPF (ICC = 0.92), but its absolute reliability was not acceptable at either 30% IPF (CV = 10.10%; ICC = 0.75) or 60% IPF (CV = 14.16%; ICC = 0.92). Mean power also exceeded the predefined CV threshold at 30% IPF (CV = 11.16%; ICC = 0.85) and at 60% IPF (CV = 14.35%; ICC = 0.89).
Conclusions
These findings suggest that the BSP protocol using functional electromechanical dynamometry is reliable for assessing mean muscle strength in trained women. However, mean velocity and mean power should be interpreted with caution, as their absolute reliability did not reach the predefined threshold of acceptable reliability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Physical Education and Sport, Faculty of Sport Sciences, University of Granada, Granada, Spain.
- Núcleo de Investigación en Salud, Actividad Física y Deportes ISAFYD, Escuela de Ciencias de la Actividad Física, Universidad de las Américas, Santiago, Chile.
- Facultad de Educación y Ciencias Sociales, Universidad Andres Bello, Entrenador Deportivo, Concepción, Chile.
- Facultad de Salud y Ciencias Sociales, Escuela de Ciencias de la Actividad Física, Universidad de las Américas, Concepción, Chile.
- Department of Sports Sciences and Physical Conditioning, Universidad Católica de la Santísima Concepción, Concepción, Chile.
- Department of Physical Education and Sport, Faculty of Physical Activity and Sports Sciences, Universidad de León, León, Spain.
ORCID-Profile: David Ulloa-Díaz, Ángela Rodríguez-Perea, Claudio Carvajal-Parodi, Álvaro Huerta Ojeda, Sergio Araya-Sierralta, Luis Javier Chirosa-Ríos
Zitieren
APA
Cifuentes-Zapata, C., Andrades-Ramírez, O., Romero-Vera, L., Ulloa-Díaz, D., Rodríguez-Perea, Á., Carvajal-Parodi, C., Huerta Ojeda, Á., Araya-Sierralta, S., & Chirosa-Ríos, L. J. (2026). Reliability of a functional electromechanical dynamometer for a bilateral standing press exercise at intensities of 30% and 60% of isometric peak force in trained women. PeerJ. https://doi.org/10.7717/peerj.21777
Vancouver
Cifuentes-Zapata C, Andrades-Ramírez O, Romero-Vera L, Ulloa-Díaz D, Rodríguez-Perea Á, Carvajal-Parodi C, et al. Reliability of a functional electromechanical dynamometer for a bilateral standing press exercise at intensities of 30% and 60% of isometric peak force in trained women. PeerJ. 2026. doi:10.7717/peerj.21777
BibTeX
@article{CifuentesZapata2026,
author = {Cifuentes-Zapata, Claudio and Andrades-Ramírez, Oscar and Romero-Vera, Luis and Ulloa-Díaz, David and Rodríguez-Perea, Ángela and Carvajal-Parodi, Claudio and Huerta Ojeda, Álvaro and Araya-Sierralta, Sergio and Chirosa-Ríos, Luis Javier},
title = {Reliability of a functional electromechanical dynamometer for a bilateral standing press exercise at intensities of 30% and 60% of isometric peak force in trained women},
journal = {PeerJ},
year = {2026},
doi = {10.7717/peerj.21777}
}