The reliability and validity of a visual analog scale for rating the single leg squat test
PeerJ · 28.07.2026 · 14 · e21600
DOI: 10.7717/peerj.21600 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift PeerJ, online erschienen am 28.07.2026. Verfasst von Yongni Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Duquesne-China Health Institute, Rangos School of Health Sciences, Duquesne University, Pittsburgh, PA, United States of America. Hauptthemen laut MEDLINE: Visual Analog Scale, Lower Extremity, Exercise Test, Leg Injuries. Die Arbeit nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
The single leg squat test (SLST) is commonly used for visual movement assessment in subjects with lower extremity injuries. While current methods utilize ordinal rating categorization, adopting a visual analog scale (VAS) may offer potential advantages. The study aims to determine the intra-rater, inter-rater reliability, and validity of a visual analog scale (VAS) for rating the single leg squat test (SLST) in subjects with lower extremity injuries.
Methods
58 subjects with lower extremity injuries participated. Intra-rater reliability was assessed by a physical therapist at 1-week and 2-week intervals. Single session inter-rater reliability was assessed by two physical therapists. A 10 cm VAS was used to measure trunk lateral flexion, hip adduction, and dynamic knee valgus during the SLST. Intra-class correlation coefficients (ICC) assessed intra-rater and inter-rater reliability. Validity was assessed by comparing VAS scores to 2-D kinematic analysis.
Results
Intra-rater reliability was good at both 1 week (ICC = 0.81–0.92, MDC = 1.2–2.2 cm) and 2 weeks (ICC = 0.77–0.79, MDC = 2.7–3 cm). Inter-rater reliability was good to excellent (ICC = 0.78–0.93, MDD = 1–2.6 cm). The correlation between visual assessment and 2-D kinematic analysis was moderate to good ( r = 0.66–0.78).
Conclusion
Preliminary data indicate that VAS reliably and validly rates SLST in individuals with lower-extremity injuries, allowing calculation of minimal detectable change and minimal detectable difference to support clinical interpretation. The MDC and MDD values established for trunk lateral flexion, hip adduction, and dynamic knee valgus allows clinicians to objectively determine if scores between repeated measurement and two raters are different.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Duquesne-China Health Institute, Rangos School of Health Sciences, Duquesne University, Pittsburgh, PA, United States of America.
- Department of Rehabilitation Therapy, Shanghai Yangzhi Rehabilitation Hospital (Shanghai Sunshine Rehabilitation Center), School of Medicine, Tongji University, Shanghai, China.
- Department of Kinesiology, Colorado Mesa University, Colorado, United States of America.
- Physical Therapy, Duquesne University, Pittsburgh, PA, United States of America.
- UPMC Center for Sports Medicine, Pittsburgh, PA, United States of America.
- Bone and Joint Rehabilitation Center, Shanghai Yangzhi Rehabilitation Hospital (Shanghai Sunshine Rehabilitation Center), School of Medicine, Tongji University, Shanghai, China.
Zitieren
APA
Zhang, Y., Liu, Y., Huang, X., Carcia, C. R., Martin, R. L., & Pan, Z. (2026). The reliability and validity of a visual analog scale for rating the single leg squat test. PeerJ, 14, e21600. https://doi.org/10.7717/peerj.21600
Vancouver
Zhang Y, Liu Y, Huang X, Carcia CR, Martin RL, Pan Z. The reliability and validity of a visual analog scale for rating the single leg squat test. PeerJ. 2026;14:e21600. doi:10.7717/peerj.21600
BibTeX
@article{Zhang2026,
author = {Zhang, Yongni and Liu, Yifan and Huang, Xinwei and Carcia, Christopher R and Martin, RobRoy L and Pan, Zhicheng},
title = {The reliability and validity of a visual analog scale for rating the single leg squat test},
journal = {PeerJ},
year = {2026},
volume = {14},
pages = {e21600},
doi = {10.7717/peerj.21600}
}
EUVIMED