EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of dosimetric consistency between pre- and postoperative CT-guided noncoplanar template-assisted ¹²⁵I seed implantation in recurrent and metastatic thoracic tumors: a retrospective study

Lingyun Qiu, Yucheng Li, Rong Wu, Yinan Chen, Ziguo Zhang, Wenming Zhan, Yinghao Zhang, Qiang Li, Aihong Bi, Limin Luo, Weijun Chen, Zhiwen Yan

PeerJ · 22.05.2026 · 14 · e21324

DOI: 10.7717/peerj.21324 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PeerJ, online erschienen am 22.05.2026. Verfasst von Lingyun Qiu und 11 weiteren Autor:innen. Beteiligte Einrichtung: Cancer Center, Department of Radiation Oncology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hang…. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Iodine Radioisotopes, Thoracic Neoplasms, Neoplasm Recurrence, Local. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Physical Technology Special Committee of the Zhejiang Provincial Anti-Cancer Association, Zhejiang Provincial Department of Education General Scientific Research Project, Medical and Health Research Project of Zhejiang Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Recurrent and metastatic thoracic malignancies remain challenging to manage because of their proximity to vital structures and the impact of respiratory motion on dose accuracy. This retrospective study aimed to assess the dosimetric consistency between preoperative planning and postoperative verification in computed tomography (CT)-guided 3D-printed noncoplanar template (3DPNCT)-assisted ¹²⁵I seed implantation.

Methods

Clinical and dosimetric data from 32 patients who underwent 3DPNCT-assisted seed implantation were retrospectively reviewed. Preoperative treatment plans were compared with postoperative dose verification to evaluate deviations in key indices, including target coverage, dose conformity, and homogeneity. Statistical comparisons were performed using appropriate paired analyses, and agreement between planned and delivered doses was further evaluated through Bland–Altman analysis.

Results

The mean D90 decreased from 142.47 ± 28.90 Gy to 135.06 ± 31.66 Gy ( p = 0.022). The mean V100 decreased from 93.19 ± 14.74% to 91.48 ± 12.37% ( p = 0.441), and V150 from 73.81 ± 16.20% to 69.30 ± 17.61% ( p = 0.059). No significant differences were observed in V200, CI, or EI (all p > 0.05). The homogeneity index (HI) increased slightly from 0.222 ± 0.114 to 0.257 ± 0.130 ( p = 0.049).

Conclusions

CT-guided 3DPNCT-assisted ¹²⁵I seed implantation achieves robust dosimetric reproducibility and favorable plan accuracy in thoracic tumors. Despite minor deviations related to respiratory motion and intraoperative uncertainties, this approach provides a reliable and clinically feasible option for managing complex thoracic malignancies. Further prospective studies incorporating motion management and real-time adaptive planning are warranted to optimize its clinical application.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedIodine RadioisotopesThoracic NeoplasmsNeoplasm Recurrence, LocalBrachytherapyLung NeoplasmsHumansRetrospective StudiesFemaleMaleMiddle AgedAgedRadiotherapy DosageRadiotherapy Planning, Computer-AssistedAdult

Stichwörter der Autor:innen

CT-guided brachytherapyDosimetryNoncoplanar templateRadioactive seed implantationRetrospective studyThoracic tumors

Substanzen

Iodine RadioisotopesIodine-125

Autor:innen und Institutionen

  • Cancer Center, Department of Radiation Oncology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, Zhejiang, China.
  • Department of Breast Surgery, Hangzhou TCM Hospital Affiliated to Zhejiang Chinese Medical University, Hangzhou Hospital of Traditional Chinese Medicine, Hangzhou, Zhejiang, China.
  • School of Medical Technology, Yunnan Engineering Vocational College, Yunnan, China.
  • School of National Defence Science & Technology, Southwest University of Science and Technology, Mianyang, Sichuan, China.
  • Cancer Center, Clinical Medical Engineering Department, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, Zhejiang, China.

Förderung

  • Physical Technology Special Committee of the Zhejiang Provincial Anti-Cancer Association
  • Zhejiang Provincial Department of Education General Scientific Research Project
  • Medical and Health Research Project of Zhejiang Province

Zitieren

APA

Qiu, L., Li, Y., Wu, R., Chen, Y., Zhang, Z., Zhan, W., Zhang, Y., Li, Q., Bi, A., Luo, L., Chen, W., & Yan, Z. (2026). Evaluation of dosimetric consistency between pre- and postoperative CT-guided noncoplanar template-assisted ¹²⁵I seed implantation in recurrent and metastatic thoracic tumors: a retrospective study. PeerJ, 14, e21324. https://doi.org/10.7717/peerj.21324

Vancouver

Qiu L, Li Y, Wu R, Chen Y, Zhang Z, Zhan W, et al. Evaluation of dosimetric consistency between pre- and postoperative CT-guided noncoplanar template-assisted ¹²⁵I seed implantation in recurrent and metastatic thoracic tumors: a retrospective study. PeerJ. 2026;14:e21324. doi:10.7717/peerj.21324

BibTeX
@article{Qiu2026,
  author = {Qiu, Lingyun and Li, Yucheng and Wu, Rong and Chen, Yinan and Zhang, Ziguo and Zhan, Wenming and Zhang, Yinghao and Li, Qiang and Bi, Aihong and Luo, Limin and Chen, Weijun and Yan, Zhiwen},
  title = {Evaluation of dosimetric consistency between pre- and postoperative CT-guided noncoplanar template-assisted ¹²⁵I seed implantation in recurrent and metastatic thoracic tumors: a retrospective study},
  journal = {PeerJ},
  year = {2026},
  volume = {14},
  pages = {e21324},
  doi = {10.7717/peerj.21324}
}
Kostenlos starten →