Comparison of air displacement plethysmography and octopolar multifrequency bioelectrical impedance analysis in NCAA Division I male lacrosse athletes

Jason Curtis Sawyer, Jennifer Elise Hurrell

PeerJ · 27.05.2026 · 14 · e21301

DOI: 10.7717/peerj.21301 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift PeerJ, online erschienen am 27.05.2026. Verfasst von Jason Curtis Sawyer und 1 weiteren Autor:innen. Beteiligte Einrichtung: Biological and Biomedical Sciences Department, School of Health and Behavioral Sciences, Bryant University, Smithfield, RI, United States of America. Hauptthemen laut MEDLINE: Electric Impedance, Body Composition, Plethysmography, Lacrosse. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Body composition is an important determinant of general health and, in athletes, is often associated with sports performance and injury risk. The purpose of this investigation was to compare body composition measurements gathered through octopolar multifrequency bioelectrical impedance analysis (O-MF-BIA) and air displacement plethysmography (ADP) in Division I lacrosse athletes. Materials and Methods Fifty-four male lacrosse players underwent body composition testing using O-MF-BIA and ADP during preseason. Measures of percent body fat (PBF), total fat mass (FM), and total fat-free mass (FFM) were collected using both devices.

Results

There was no statistical difference between O-MF-BIA and ADP for mean values of FFM ( M = 0.365 kg., p = .164), FM ( M = − 0.204 kg., p = .291), and PBF ( M = −0.222%., p = .302). There was a statistically significant, strong correlation between the O-MF-BIA and ADP for FFM ( r (52) = .92, p < .001), FM ( r (52) = .75, p < .001) and PBF ( r (52) = .70, p < .001). Limits of agreement (LOA) between O-MF-BIA and ADP were determined using Bland-Altman plots for FFM (LOA –4.946 to 5.675), FM (LOA –5.499 to 5.092), and PBF (LOA –6.343 to 5.899).

Conclusion

Body composition measurements obtained by O-MF-BIA and ADP were similar; however, the wide LOA indicates caution should be used when using the devices interchangeably.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electric ImpedanceBody CompositionPlethysmographyLacrosseAthletesHumansMaleYoung AdultAdult

Stichwörter der Autor:innen

Agreement analysisFat massFat-free massLimits of agreementPercent body fat

Autor:innen und Institutionen

  • Biological and Biomedical Sciences Department, School of Health and Behavioral Sciences, Bryant University, Smithfield, RI, United States of America.

Zitieren

APA

Sawyer, J. C., & Hurrell, J. E. (2026). Comparison of air displacement plethysmography and octopolar multifrequency bioelectrical impedance analysis in NCAA Division I male lacrosse athletes. PeerJ, 14, e21301. https://doi.org/10.7717/peerj.21301

Vancouver

Sawyer JC, Hurrell JE. Comparison of air displacement plethysmography and octopolar multifrequency bioelectrical impedance analysis in NCAA Division I male lacrosse athletes. PeerJ. 2026;14:e21301. doi:10.7717/peerj.21301

BibTeX
@article{Sawyer2026,
  author = {Sawyer, Jason Curtis and Hurrell, Jennifer Elise},
  title = {Comparison of air displacement plethysmography and octopolar multifrequency bioelectrical impedance analysis in NCAA Division I male lacrosse athletes},
  journal = {PeerJ},
  year = {2026},
  volume = {14},
  pages = {e21301},
  doi = {10.7717/peerj.21301}
}
Kostenlos starten →