Comparison of XEN gel stent for management of open-angle glaucoma: a systematic review and meta-analysis

Xiangjun Fu, Guoliang Li, Juan He, Hongyi Luo, Ruijue Peng, Yilian Cheng, Jie Peng, Shiyan Chen, Chao Qu

PeerJ · 09.06.2026 · 14 · e21133

DOI: 10.7717/peerj.21133 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift PeerJ, online erschienen am 09.06.2026. Verfasst von Xiangjun Fu und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine, University of Electronic Science and Technology of China, Chengdu, China. Hauptthemen laut MEDLINE: Glaucoma, Open-Angle, Stents, Phacoemulsification. Die Arbeit nennt 98 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Natural Science Foundation of Sichuan, China, Department of Science and Technology Foundation of Chengdu, Sichuan, China, Interdisciplinary Project between Electronic Science and Technology University and Medical Engineering of Chengdu, Sichuan, China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The comparative efficacy of XEN gel stent implantation, either as a standalone procedure (XEN-only) or combined with phacoemulsification (Phaco-XEN), for the treatment of open-angle glaucoma (OAG) warrants further investigation. This systematic review and meta-analysis evaluated the efficacy of XEN-only and Phaco-XEN procedures compared to trabeculectomy (TB).

Methods

Five major electronic databases, including PubMed, ScienceDirect, and the Cochrane Library, were systematically searched from inception to September 1, 2025. We compared clinical outcomes among XEN-only, Phaco-XEN, and TB groups. Stratification analyses examined outcomes based on follow-up duration and geographic location. Efficacy endpoints included intraocular pressure (IOP), number of anti-glaucoma medications (NOAM), and bleb needling rates. Sensitivity analyses were performed to assess potential biases.

Results

A total of 56 eligible studies were included. (1) Both XEN-only and Phaco-XEN procedures achieved significant IOP reductions from baseline ( P < 0.001). When comparing XEN-only versus Phaco-XEN, no statistically significant differences were observed in postoperative IOP (MD: −0.22; P = 0.06), NOAM (MD: 0.10; P = 0.06), or bleb needling rates (RR: 1.79; P = 0.06). (2) Compared with trabeculectomy (TB), there was no significant difference in postoperative NOAM for XEN-only (MD: −0.16; P = 0.16), but XEN-only had lower postoperative IOP (MD: −0.93; P = 0.0003). However, extremely high heterogeneity ( I 2 = 86%) suggests this finding should be interpreted with caution. Conversely, XEN-only surgery was associated with a significantly higher rate of bleb needling compared to TB surgery (RR: 3.09; P = 0.001). Hyphema and bleb needling were identified as the most frequent postoperative complications.

Conclusion

Both XEN-only and Phaco-XEN surgeries provide effective IOP reduction. There was no statistically significant difference in postoperative NOAM reduction between XEN-only and Phaco-XEN surgeries ( P = 0.06). TB surgery remains superior regarding lower postoperative bleb needling rates compared to XEN-only surgery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Glaucoma, Open-AngleStentsPhacoemulsificationHumansTrabeculectomyIntraocular PressureTreatment Outcome

Stichwörter der Autor:innen

Glaucoma surgeryMinimally invasive glaucoma surgeryOpen-angle glaucomaXEN gel stent

Autor:innen und Institutionen

  • School of Medicine, University of Electronic Science and Technology of China, Chengdu, China.
  • Chengdu University of Traditional Chinese Medicine, Chengdu, China.
  • Sichuan Provincial People's Hospital, Chengdu, China.
  • Sichuan Key Laboratory for Disease Gene Study Chinese Academy of Sciences Sichuan Translational Medicine Research Hospital, Chengdu, Sichuan Province, China.

Förderung

  • The Natural Science Foundation of Sichuan, China
  • Department of Science and Technology Foundation of Chengdu, Sichuan, China
  • Interdisciplinary Project between Electronic Science and Technology University and Medical Engineering of Chengdu, Sichuan, China

Zitieren

APA

Fu, X., Li, G., He, J., Luo, H., Peng, R., Cheng, Y., Peng, J., Chen, S., & Qu, C. (2026). Comparison of XEN gel stent for management of open-angle glaucoma: a systematic review and meta-analysis. PeerJ, 14, e21133. https://doi.org/10.7717/peerj.21133

Vancouver

Fu X, Li G, He J, Luo H, Peng R, Cheng Y, et al. Comparison of XEN gel stent for management of open-angle glaucoma: a systematic review and meta-analysis. PeerJ. 2026;14:e21133. doi:10.7717/peerj.21133

BibTeX
@article{Fu2026,
  author = {Fu, Xiangjun and Li, Guoliang and He, Juan and Luo, Hongyi and Peng, Ruijue and Cheng, Yilian and Peng, Jie and Chen, Shiyan and Qu, Chao},
  title = {Comparison of XEN gel stent for management of open-angle glaucoma: a systematic review and meta-analysis},
  journal = {PeerJ},
  year = {2026},
  volume = {14},
  pages = {e21133},
  doi = {10.7717/peerj.21133}
}
Kostenlos starten →