EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

High-fluorescent cells as a rapid screening tool for malignant effusions

Hongmei Ding, Yuexinzi Jin, Chu Chu, Lin Wang

PeerJ · 2025

DOI: 10.7717/peerj.20528 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PeerJ, 2025. Verfasst von Hongmei Ding und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China. Hauptthemen laut MEDLINE: Pleural Effusion, Malignant, Pericardial Effusion. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, The National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Elevated levels of high-fluorescent cells (HFCs) in serous effusions often suggest the presence of tumor cells. The purpose of this study was to evaluate the diagnostic value of HFC detection in the differentiation between benign and malignant serous effusions using the Sysmex XN-10 automated hematology analyzer in body fluid mode (BF mode).

Methods

Serous effusion specimens, including 702 pleural effusions, 255 ascitic fluid samples and 21 pericardial effusions, were collected from 978 patients at the First Affiliated Hospital with Nanjing Medical University between June 2023 and June 2024. The absolute number (HFC#) and percentage (HFC%) of HFCs were detected using the Sysmex XN-10 automated hematology analyzer. Meanwhile, levels of carcinoembryonic antigen (CEA), lactate dehydrogenase (LDH) and other biomarkers in serous effusions were measured. The diagnostic performance for malignant effusions was evaluated using receiver operating characteristic (ROC) curves.

Results

The HFC#, HFC% and CEA levels in the malignant effusion group were significantly higher than those in the benign effusion group (all P < 0.001). Multivariate logistic regression analysis revealed that HFC#, HFC%, CEA, and LDH were independently associated with malignant effusion. Receiver operating characteristic (ROC) analysis showed that CEA had the best diagnostic performance (AUC = 0.817), followed by HFC% (AUC = 0.727) and HFC# (AUC = 0.703). The diagnostic performance of HFC in combination with CEA is significantly better than that of CEA alone. For malignant effusions associated with lung cancer, the diagnostic performance of CEA was better than HFC and cytokeratin 19 fragment (CYFRA21-1), but there was no significant difference between HFC and CYFRA21-1.

Conclusion

HFC demonstrates high diagnostic value in identifying malignant serous effusions, especially when used in combination with CEA. As a rapid laboratory parameter based on cellular nucleic acid characteristics, HFC can serve as a useful auxiliary tool for screening malignant effusions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pleural Effusion, MalignantPericardial EffusionHumansMaleFemaleMiddle AgedAgedCarcinoembryonic AntigenL-Lactate DehydrogenaseROC CurveAscitic FluidBiomarkers, TumorAdultPleural EffusionAged, 80 and over

Stichwörter der Autor:innen

Carcinoembryonic antigenDiagnostic performanceHigh-fluorescent cellsLung cancerSerous effusion

Substanzen

Carcinoembryonic AntigenL-Lactate DehydrogenaseBiomarkers, Tumor

Autor:innen und Institutionen

  • Department of Laboratory Medicine, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China.
  • Branch of National Clinical Research Center for Laboratory Medicine, Nanjing, China.

Förderung

  • National Natural Science Foundation of China
  • The National Natural Science Foundation of China

Zitieren

APA

Ding, H., Jin, Y., Chu, C., & Wang, L. (2025). High-fluorescent cells as a rapid screening tool for malignant effusions. PeerJ. https://doi.org/10.7717/peerj.20528

Vancouver

Ding H, Jin Y, Chu C, Wang L. High-fluorescent cells as a rapid screening tool for malignant effusions. PeerJ. 2025. doi:10.7717/peerj.20528

BibTeX
@article{Ding2025,
  author = {Ding, Hongmei and Jin, Yuexinzi and Chu, Chu and Wang, Lin},
  title = {High-fluorescent cells as a rapid screening tool for malignant effusions},
  journal = {PeerJ},
  year = {2025},
  doi = {10.7717/peerj.20528}
}
Kostenlos starten →