Easier said than done: unexpected hurdles to preparing ∼1,000 cranial CT scans for data collection from an online digital repository
PeerJ · 20.10.2025 · 13 · e20172
DOI: 10.7717/peerj.20172 ↗Kurz gefasst
Fachartikel in der Zeitschrift PeerJ, online erschienen am 20.10.2025. Verfasst von Mario Modesto-Mata und 8 weiteren Autor:innen. Beteiligte Einrichtung: Centro Nacional de Investigación sobre la Evolución Humana, Burgos, Castilla y León, Spain. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Skull, Data Collection. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 88 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Research Council within the European Union’s Horizon Europe, Ministerio de Ciencia e Innovación Project, Southwest National Primate Research Center.
Abstract (Originalsprache)
Background
As science becomes more open and accessible, researchers are increasingly encouraged—and sometimes required—to share their digital data on public repositories. While this promotes transparency and reusability, it can also introduce challenges. We highlight one such challenge by detailing our experience processing computerized tomography (CT) scans of 985 baboon skulls downloaded from MorphoSource, part of a quantitative genetic study of craniodental variation in the pedigreed baboon colony from the Southwest National Primate Research Center. When importing DICOM files into 3D Slicer, 182 of the 985 scans (18.5%) generated an “inconsistent slice spacing” error. When prompted, 3D Slicer “corrected” this by regularizing the slice spacing. However, this led to a mismatch between the slice spacing reported on MorphoSource and the spacing adjusted by 3D Slicer.
Methods
To determine which slice spacing was accurate, we compared Prosthion-Basion (PR-BA) distances measured directly from physical skulls (using calipers and a Microscribe) with those derived from the CT models. We ran paired t -tests to determine whether there were differences between them. Our comparison sample included five randomly selected skulls from the error group and fifteen ramdon skulls from the error-free group (which exhibited various slice spacings when scanned).
Results
For scans without the slice spacing error, there was strong agreement between physical and digital measurements, indicating metadata accuracy. For error-generating scans, measurements based on 3D Slicer’s corrected spacing and Amira-Avizo both aligned well with the physical data. In contrast, manually overriding the spacing to match the MorphoSource metadata led to overestimations of the PR-BA distance.
Conclusion
Although the discrepancy was straightforward to describe, resolving it required over 250 person-hours across 8 months. Accessing physical specimens, conducting repeated measurements, and cross-validating with multiple tools made the process labor-intensive. Nonetheless, this effort avoided a 3–5% measurement bias in nearly 20% of our sample and allowed inclusion of these scans in downstream semi-automated data collection. We urge researchers to thoroughly understand the digital datasets they work with and resist the temptation to ignore apparent errors during import. We also recommend that funding bodies provide support for the extensive time needed to validate and process digital imagery, both for data generators and users. Finally, we highlight the need for public repositories to implement stronger quality control. If a data import check similar to 3D Slicer’s had been applied during data submission, the inconsistency between manually entered metadata and embedded DICOM information might have been caught and corrected at the time of upload.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Centro Nacional de Investigación sobre la Evolución Humana, Burgos, Castilla y León, Spain.
- Universidad Internacional de La Rioja, Logroño, La Rioja, Spain.
- Department of Anthropology, Loyola University of Chicago, Chicago, IL, United States of America.
- Department of Pediatrics, University of Washington School of Medicine, Seattle, WA, United States of America.
- National Park Service, Ashland, WI, United States of America.
- Department of Anthropology, Pennsylvania State University, University Park, PA, United States of America.
Förderung
- European Research Council within the European Union’s Horizon Europe
- Ministerio de Ciencia e Innovación Project
- Southwest National Primate Research Center
- NIH HHS
Zitieren
APA
Modesto-Mata, M., Thiebaut, A., Krueger, K. L., Maga, A. M., Joganic, J. L., Ryan, T. M., Richtsmeier, J. T., Cheverud, J. M., & Hlusko, L. J. (2025). Easier said than done: unexpected hurdles to preparing ∼1,000 cranial CT scans for data collection from an online digital repository. PeerJ, 13, e20172. https://doi.org/10.7717/peerj.20172
Vancouver
Modesto-Mata M, Thiebaut A, Krueger KL, Maga AM, Joganic JL, Ryan TM, et al. Easier said than done: unexpected hurdles to preparing ∼1,000 cranial CT scans for data collection from an online digital repository. PeerJ. 2025;13:e20172. doi:10.7717/peerj.20172
BibTeX
@article{ModestoMata2025,
author = {Modesto-Mata, Mario and Thiebaut, Arthur and Krueger, Kristin L and Maga, A Murat and Joganic, Jessica L and Ryan, Timothy M and Richtsmeier, Joan T and Cheverud, James M and Hlusko, Leslea J},
title = {Easier said than done: unexpected hurdles to preparing ∼1,000 cranial CT scans for data collection from an online digital repository},
journal = {PeerJ},
year = {2025},
volume = {13},
pages = {e20172},
doi = {10.7717/peerj.20172}
}
EUVIMED