Intra- and inter-rater reliability of ultrasound measurements of the levator ani muscle thickness in and M-mode in asymptomatic individuals: a cross-sectional study
PeerJ · 2025
DOI: 10.7717/peerj.19427 ↗Kurz gefasst
Querschnittstudie in der Zeitschrift PeerJ, 2025. Verfasst von Esther Delgado-Pérez und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physiotherapy, Faculty of Medicine, Health and Sports, European University of Madrid, Villaviciosa de Odón, Madrid, Spain. Hauptthemen laut MEDLINE: Pelvic Floor, Muscle Contraction, Muscle, Skeletal. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC0).
Abstract (Originalsprache)
Background
The levator ani muscle (LAM) plays a crucial role in maintaining pelvic floor function, providing support to pelvic organs and assisting in physiological processes such as micturition and defecation. Ultrasound imaging, particularly M-mode ultrasound, has been increasingly employed in the evaluation of pelvic floor muscle activity.
Objectives
The goal of the present study was to assess the intra- and inter-rater reliability of M-mode ultrasound measurements of LAM thickness, muscle activation speed, and contraction time during a 5-s sustained pelvic floor contraction in asymptomatic women.
Methods
Thirty-four healthy nulliparous women aged 18 to 25 were recruited for this cross-sectional study. Transabdominal M-mode ultrasound was used to measure the intra- and inter-rater reliability of LAM thickness during maximum pelvic floor contraction. Each participant performed three pelvic floor contractions, with measurements repeated twice.
Results
Intra-rater reliability ranged from poor to good reliability for LAM thickness (ICC = 0.621–0.899), with similar results for pelvic rise time and contraction velocity. Inter-rater reliability was excellent for LAM thickness (ICC = 0.910) but only fair for pelvic rise time and contraction velocity (ICC = 0.673–0.647).
Conclusions
M-mode ultrasound imaging demonstrates excellent inter-rater reliability for LAM thickness measurement and fair intra-rater reliability for other functional variables. This technique appears to be a promising method for evaluating pelvic floor muscle activity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Physiotherapy, Faculty of Medicine, Health and Sports, European University of Madrid, Villaviciosa de Odón, Madrid, Spain.
- Neurosciences & Physical Therapy Research Group. Department of Physiotherapy, Faculty of Medicine, Health and Sports, European University of Madrid, Villaviciosa de Odón, Madrid, Spain.
ORCID-Profile: Esther Delgado-Pérez, Alberto Bermejo-Franco, Vanesa Abuín-Porras, Carlos Romero-Morales
Zitieren
APA
Delgado-Pérez, E., Bermejo-Franco, A., Díaz-Meco, R., Abuín-Porras, V., Romero-Morales, C., González-Fernández, L., & De-La Cueva-Reguera, M. (2025). Intra- and inter-rater reliability of ultrasound measurements of the levator ani muscle thickness in and M-mode in asymptomatic individuals: a cross-sectional study. PeerJ. https://doi.org/10.7717/peerj.19427
Vancouver
Delgado-Pérez E, Bermejo-Franco A, Díaz-Meco R, Abuín-Porras V, Romero-Morales C, González-Fernández L, et al. Intra- and inter-rater reliability of ultrasound measurements of the levator ani muscle thickness in and M-mode in asymptomatic individuals: a cross-sectional study. PeerJ. 2025. doi:10.7717/peerj.19427
BibTeX
@article{DelgadoPrez2025,
author = {Delgado-Pérez, Esther and Bermejo-Franco, Alberto and Díaz-Meco, Raquel and Abuín-Porras, Vanesa and Romero-Morales, Carlos and González-Fernández, Laura and De-La Cueva-Reguera, Mónica},
title = {Intra- and inter-rater reliability of ultrasound measurements of the levator ani muscle thickness in and M-mode in asymptomatic individuals: a cross-sectional study},
journal = {PeerJ},
year = {2025},
doi = {10.7717/peerj.19427}
}
EUVIMED