Measurements of white-to-white corneal diameter and anterior chamber parameters using the Pentacam AXL wave and their correlations in the adult Saudi population
PeerJ · 2025
DOI: 10.7717/peerj.19227 ↗Kurz gefasst
Fachartikel in der Zeitschrift PeerJ, 2025. Verfasst von Wafa M Alotaibi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Optometry and Visual Sciences, College of Applied Medicine Sciences, King Saud University, Riyadh, Saudi Arabia. Hauptthemen laut MEDLINE: Corneal Topography, Cornea, Anterior Chamber. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deanship of Scientific Research and the College of Applied Medical Sciences Research Center at King Saud University.
Abstract (Originalsprache)
Background
Assessment of eye parameters such as the white-to-white (WTW) corneal diameter, anterior chamber depth (ACD), and anterior chamber angle (ACA) are essential for preoperative evaluation of refractive surgery and diagnosing and managing some ocular diseases.
Objective
To report the distribution and association between white-to-white corneal diameter and anterior chamber parameters in the Saudi adult population.
Methods
Cross-sectional prospective study consisting of 82 Saudi adults. White-to-white corneal diameter, anterior chamber angle, anterior chamber depth, and axial length were collected from healthy subjects using the Pentacam AXL Wave in a tertiary eye care setting.
Results
Mean white-to-white corneal diameter, anterior chamber angle, anterior chamber depth, and axial length were 11.95 ± 0.39 mm, 37.94 ± 5.01°, 2.97 ± 0.31 mm and 23.93 ± 0.97 mm, respectively. A significant moderate correlation was found between white-to-white corneal diameter and anterior chamber angle (r = 0.31, p ≤ 0.01), anterior chamber depth (r = 0.49, p ≤ 0.01), and axial length (r = 0.50, p ≤ 0.01) and between anterior chamber angle and anterior chamber depth (r = 0.71, p ≤ 0.01). Furthermore, age was moderately correlated with anterior chamber angle (r = 0.44, p 0.01) and anterior chamber depth (r = 0.39, p 0.01) and weakly correlated with white-to-white corneal diameter (r =0.17, p = 0.12). Males had a significantly ( p < 0.01) higher white-to-white corneal diameter (12.12 ± 0.38 mm) than females (11.84 ± 0.36.mm).
Conclusion
Reference values for white-to-white corneal diameter and anterior chamber parameters would help eye care professionals choose the right lenses for cataract and refractive surgeries as well as in diagnosing glaucoma and corneal disorders.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Optometry and Visual Sciences, College of Applied Medicine Sciences, King Saud University, Riyadh, Saudi Arabia.
- Department of Optometry, College of Applied Medical Sciences, Qassim University, Buraydah, Saudi Arabia.
ORCID-Profile: Naveen Challa, Saif Hassan Alrasheed
Förderung
- Deanship of Scientific Research and the College of Applied Medical Sciences Research Center at King Saud University
Zitieren
APA
Alotaibi, W. M., Challa, N., Alrasheed, S. H., & Abanmi, R. N. (2025). Measurements of white-to-white corneal diameter and anterior chamber parameters using the Pentacam AXL wave and their correlations in the adult Saudi population. PeerJ. https://doi.org/10.7717/peerj.19227
Vancouver
Alotaibi WM, Challa N, Alrasheed SH, Abanmi RN. Measurements of white-to-white corneal diameter and anterior chamber parameters using the Pentacam AXL wave and their correlations in the adult Saudi population. PeerJ. 2025. doi:10.7717/peerj.19227
BibTeX
@article{Alotaibi2025,
author = {Alotaibi, Wafa M and Challa, Naveen and Alrasheed, Saif Hassan and Abanmi, Rahaf Nasser},
title = {Measurements of white-to-white corneal diameter and anterior chamber parameters using the Pentacam AXL wave and their correlations in the adult Saudi population},
journal = {PeerJ},
year = {2025},
doi = {10.7717/peerj.19227}
}
EUVIMED