EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

The effect of varying thicknesses of mineral trioxide aggregate (MTA) and Biodentine as apical plugs on the fracture resistance of teeth with simulated open apices: a comparative in vitro study

Pankaj Panjwani, Kulvinder Banga, Jatin Atram, Dian Agustin Wahjuningrum iD, Alexander Maniangat Luke iD, Krishna Prasad Shetty, Ajinkya M Pawar iD

PeerJ · 18.12.2024 · 12 · e18691

DOI: 10.7717/peerj.18691 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift PeerJ, online erschienen am 18.12.2024. Verfasst von Pankaj Panjwani und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Conservative Dentistry and Endodontics, Nair Hospital Dental College, Mumbai, Maharashtra, India. Hauptthemen laut MEDLINE: Silicates, Calcium Compounds, Oxides, Drug Combinations. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

This study evaluates the fracture resistance of apical plugs created from Biodentine and mineral trioxide aggregate (MTA) in thicknesses of 3 and 5 mm within simulated open apex tooth models.

Methods

Fifty human maxillary central incisors were obtained from a pool of freshly extracted teeth. In order to replicate open apices without cavity preparation, ten teeth in the control group received apical-to-coronal preparation with Peeso reamers. The remaining 40 teeth were randomly assigned to four experimental groups and received either 3 or 5 mm Biodentine or MTA apical plugs.

Results

The mean fracture loads observed in this study were as follows: control group, 431.48 N (±34.55); 3 mm MTA, 774.88 N (±62.74); 5 mm MTA, 752.65 N (±73.79); 3 mm Biodentine, 918.25 N (±59.09); and 5 mm Biodentine, 903.42 N (±24.48). Specifically, teeth in the Biodentine group demonstrated considerably stronger fracture resistance compared to those in the MTA group ( p < 0.001). However, no significant differences were observed between the 3 and 5 mm thicknesses (MTA: p = 0.98, Biodentine: p = 0.99), suggesting that plug thickness did not affect fracture resistance within both groups.

Conclusion

Biodentine apical plugs provided the highest fracture resistance among the materials, regardless of thickness.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SilicatesCalcium CompoundsOxidesDrug CombinationsAluminum CompoundsTooth FracturesHumansRoot Canal Filling MaterialsTooth ApexIncisorIn Vitro TechniquesMaterials Testing

Stichwörter der Autor:innen

Apical plugBiodentineFracture resistanceMTAOpen apex

Substanzen

SilicatesCalcium CompoundsOxidesDrug Combinationstricalcium silicatemineral trioxide aggregateAluminum CompoundsRoot Canal Filling Materials

Autor:innen und Institutionen

  • Department of Conservative Dentistry and Endodontics, Nair Hospital Dental College, Mumbai, Maharashtra, India.
  • Department of Conservative Dentistry, Faculty of Dental Medicine, Universitas Airlangga, Surabaya, Indonesia.
  • Department of Clinical Sciences, College of Dentistry, Ajman University, Ajman, United Arab Emirates.
  • Center for Medical and Bio-Allied Health Sciences Research (CMBAHSR), Ajman University, Ajman, United Arab Emirates.
  • Department of Conservative Dentistry and Endodontics, Manipal College of Dental Science MAHE, Manipal, India.

ORCID-Profile: Dian Agustin Wahjuningrum, Alexander Maniangat Luke, Ajinkya M Pawar

Zitieren

APA

Panjwani, P., Banga, K., Atram, J., Wahjuningrum, D. A., Luke, A. M., Shetty, K. P., & Pawar, A. M. (2024). The effect of varying thicknesses of mineral trioxide aggregate (MTA) and Biodentine as apical plugs on the fracture resistance of teeth with simulated open apices: a comparative in vitro study. PeerJ, 12, e18691. https://doi.org/10.7717/peerj.18691

Vancouver

Panjwani P, Banga K, Atram J, Wahjuningrum DA, Luke AM, Shetty KP, et al. The effect of varying thicknesses of mineral trioxide aggregate (MTA) and Biodentine as apical plugs on the fracture resistance of teeth with simulated open apices: a comparative in vitro study. PeerJ. 2024;12:e18691. doi:10.7717/peerj.18691

BibTeX
@article{Panjwani2024,
  author = {Panjwani, Pankaj and Banga, Kulvinder and Atram, Jatin and Wahjuningrum, Dian Agustin and Luke, Alexander Maniangat and Shetty, Krishna Prasad and Pawar, Ajinkya M},
  title = {The effect of varying thicknesses of mineral trioxide aggregate (MTA) and Biodentine as apical plugs on the fracture resistance of teeth with simulated open apices: a comparative in vitro study},
  journal = {PeerJ},
  year = {2024},
  volume = {12},
  pages = {e18691},
  doi = {10.7717/peerj.18691}
}
Kostenlos starten →