The effect of varying thicknesses of mineral trioxide aggregate (MTA) and Biodentine as apical plugs on the fracture resistance of teeth with simulated open apices: a comparative in vitro study
PeerJ · 18.12.2024 · 12 · e18691
DOI: 10.7717/peerj.18691 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift PeerJ, online erschienen am 18.12.2024. Verfasst von Pankaj Panjwani und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Conservative Dentistry and Endodontics, Nair Hospital Dental College, Mumbai, Maharashtra, India. Hauptthemen laut MEDLINE: Silicates, Calcium Compounds, Oxides, Drug Combinations. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
This study evaluates the fracture resistance of apical plugs created from Biodentine and mineral trioxide aggregate (MTA) in thicknesses of 3 and 5 mm within simulated open apex tooth models.
Methods
Fifty human maxillary central incisors were obtained from a pool of freshly extracted teeth. In order to replicate open apices without cavity preparation, ten teeth in the control group received apical-to-coronal preparation with Peeso reamers. The remaining 40 teeth were randomly assigned to four experimental groups and received either 3 or 5 mm Biodentine or MTA apical plugs.
Results
The mean fracture loads observed in this study were as follows: control group, 431.48 N (±34.55); 3 mm MTA, 774.88 N (±62.74); 5 mm MTA, 752.65 N (±73.79); 3 mm Biodentine, 918.25 N (±59.09); and 5 mm Biodentine, 903.42 N (±24.48). Specifically, teeth in the Biodentine group demonstrated considerably stronger fracture resistance compared to those in the MTA group ( p < 0.001). However, no significant differences were observed between the 3 and 5 mm thicknesses (MTA: p = 0.98, Biodentine: p = 0.99), suggesting that plug thickness did not affect fracture resistance within both groups.
Conclusion
Biodentine apical plugs provided the highest fracture resistance among the materials, regardless of thickness.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Conservative Dentistry and Endodontics, Nair Hospital Dental College, Mumbai, Maharashtra, India.
- Department of Conservative Dentistry, Faculty of Dental Medicine, Universitas Airlangga, Surabaya, Indonesia.
- Department of Clinical Sciences, College of Dentistry, Ajman University, Ajman, United Arab Emirates.
- Center for Medical and Bio-Allied Health Sciences Research (CMBAHSR), Ajman University, Ajman, United Arab Emirates.
- Department of Conservative Dentistry and Endodontics, Manipal College of Dental Science MAHE, Manipal, India.
ORCID-Profile: Dian Agustin Wahjuningrum, Alexander Maniangat Luke, Ajinkya M Pawar
Zitieren
APA
Panjwani, P., Banga, K., Atram, J., Wahjuningrum, D. A., Luke, A. M., Shetty, K. P., & Pawar, A. M. (2024). The effect of varying thicknesses of mineral trioxide aggregate (MTA) and Biodentine as apical plugs on the fracture resistance of teeth with simulated open apices: a comparative in vitro study. PeerJ, 12, e18691. https://doi.org/10.7717/peerj.18691
Vancouver
Panjwani P, Banga K, Atram J, Wahjuningrum DA, Luke AM, Shetty KP, et al. The effect of varying thicknesses of mineral trioxide aggregate (MTA) and Biodentine as apical plugs on the fracture resistance of teeth with simulated open apices: a comparative in vitro study. PeerJ. 2024;12:e18691. doi:10.7717/peerj.18691
BibTeX
@article{Panjwani2024,
author = {Panjwani, Pankaj and Banga, Kulvinder and Atram, Jatin and Wahjuningrum, Dian Agustin and Luke, Alexander Maniangat and Shetty, Krishna Prasad and Pawar, Ajinkya M},
title = {The effect of varying thicknesses of mineral trioxide aggregate (MTA) and Biodentine as apical plugs on the fracture resistance of teeth with simulated open apices: a comparative in vitro study},
journal = {PeerJ},
year = {2024},
volume = {12},
pages = {e18691},
doi = {10.7717/peerj.18691}
}
EUVIMED