Intra-rater and inter-rater reliability of the fixed plumb line for postural and scoliosis assessment in the sagittal plane: a pilot study
PeerJ · 13.11.2024 · 12 · e18121
DOI: 10.7717/peerj.18121 ↗Kurz gefasst
Fachartikel in der Zeitschrift PeerJ, online erschienen am 13.11.2024. Verfasst von Federico Roggio und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical and Biotechnological Sciences, Section of Anatomy, Histology and Movement Science, School of Medicine, University of Catania…. Hauptthemen laut MEDLINE: Scoliosis, Observer Variation, Posture. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University Research Project, Department of Biomedical and Biotechnological Sciences (BIOMETEC), University of Catania, Italy.
Abstract (Originalsprache)
Background
The plumb line (PL) is a common tool for assessing the sagittal curvatures of the spine, but its accuracy depends on the ability of the physician to use it correctly. This study aimed to present a fixed plumb line (FPL) no longer held by a physician but fixed to a support, evaluating the reliability in posture assessment, comparing it with PL in both adolescent with and without scoliosis.
Methods
The study evaluated the sagittal distances of the spine using a PL and a FPL in 80 young adults aged between 28.7 ± 7.2 and 55 adolescents aged between 12.4 ± 2.3, with and without scoliosis. Two expert and two novice clinicians tested the patients to evaluate the intra-rater and inter-rater reliability of FPL. Each clinician assessed participants twice on the same day, with a predetermined time interval (>1 h) to reduce recall bias. Multi-factor multivariate analysis of variance and two-way analysis of variance assessed the statistical significance, while intraclass correlation coefficient (ICC), standard error of measurement (SEM) and minimum detectable change (MDC) validated FPL consistency.
Results
FPL provided an ICC coefficient >0.90 for all the measures, while PL an average of 0.70. On AIS patients, PL and FPL showed a significant difference for C7 p < 0.001 and T12 p < 0.001. The measured parameters were sensitive to gender and age for the FPL, furthermore, the C7 and L3 measurements were statistically different between PL and FPL ( p < 0.001). Intra-rater reliability results for FPL ranged from 0.94 to 0.98 across various parameters, while the SEM and MDC values underscore the valuable precision of the FPL with changes exceeding 1 cm being meaningful. These findings suggest that FPL could be a reliable and accurate tool for measuring sagittal distances of the spine in both scoliotic and non-scoliotic patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical and Biotechnological Sciences, Section of Anatomy, Histology and Movement Science, School of Medicine, University of Catania, Catania, Italy.
- Catholic University of Murcia (UCAM), PhD program in Sports Science, Universidad de Murcia, Murcia, Spain.
- Pediatric Clinic, Department of Clinical and Experimental Medicine, University Hospital A.U.O. "Policlinico-Vittorio Emanuele", University of Catania, Catania, Italy.
- Research Center on Motor Activities (CRAM), University of Catania, Catania, Italy.
- Department of Biology, Sbarro Institute for Cancer Research and Molecular Medicine, College of Science and Technology, Temple University, Philadelphia, United States of America.
Förderung
- University Research Project
- Department of Biomedical and Biotechnological Sciences (BIOMETEC), University of Catania, Italy
Zitieren
APA
Roggio, F., Trovato, B., Sortino, M., Zanghì, M., Di Brigida, C., Guglielmino, C., Lombardo, C., Loreto, C., Pavone, P., & Musumeci, G. (2024). Intra-rater and inter-rater reliability of the fixed plumb line for postural and scoliosis assessment in the sagittal plane: a pilot study. PeerJ, 12, e18121. https://doi.org/10.7717/peerj.18121
Vancouver
Roggio F, Trovato B, Sortino M, Zanghì M, Di Brigida C, Guglielmino C, et al. Intra-rater and inter-rater reliability of the fixed plumb line for postural and scoliosis assessment in the sagittal plane: a pilot study. PeerJ. 2024;12:e18121. doi:10.7717/peerj.18121
BibTeX
@article{Roggio2024,
author = {Roggio, Federico and Trovato, Bruno and Sortino, Martina and Zanghì, Marta and Di Brigida, Claudio and Guglielmino, Claudia and Lombardo, Claudia and Loreto, Carla and Pavone, Piero and Musumeci, Giuseppe},
title = {Intra-rater and inter-rater reliability of the fixed plumb line for postural and scoliosis assessment in the sagittal plane: a pilot study},
journal = {PeerJ},
year = {2024},
volume = {12},
pages = {e18121},
doi = {10.7717/peerj.18121}
}