EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effect of duration and infection control barriers of light curing unit on hardness of Bulk Fill composite resin

Xinmin He, Denghui Zhang iD, Shuli Deng

PeerJ · 2024

DOI: 10.7717/peerj.18021 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PeerJ, 2024. Verfasst von Xinmin He und 2 weiteren Autor:innen. Beteiligte Einrichtung: Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, …. Hauptthemen laut MEDLINE: Composite Resins, Curing Lights, Dental, Hardness, Materials Testing. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Key R&D program of Zhejiang, General Research Project of Zhejiang Provincial Department of Education.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

This study aimed to investigate the impact of the duration of light curing unit (LCU) usage and the use of infection control barriers on the hardness of Bulk Fill composite resin after curing. The hypotheses were that extended usage of the LCU would not reduces its output power and resin hardness, and that the presence of polyethylene film barriers exacerbates the reduction in resin hardness.

Methods

Based on the absence or presence of polyethylene film (PE) and the number of layers used, a 3M LED curing light (EliparTM DeepCure-S; 3M ESPE, St Paul, MN, USA) was divided into three groups: PE0, PE1, and PE3. The curing light was used 30 times daily for 20 s per exposure, at frequencies of 0, 6, and 12 months. Maximum output power tests were conducted for each group of curing lights. Custom-made plastic modules were used to stack Bulk Fill composite resin (Filtek Bulk Fill Posterior Restorative; 3M ESPE) to a thickness of 4 mm. Each group of curing lights was used to cure the modules in a direct contact manner for 20 s. Vickers hardness measurements were taken at the top and bottom surfaces of the resin specimens using a digital microhardness tester. A one-way or two-way ANOVA analyzed the power of LCUs, Vickers hardness of Bulk Fill composite resin, and hardness decrease percentage across groups. Pairwise comparisons used the Tukey test (α = 0.05).

Results

As the duration of usage increased, both the power of the curing light and the hardness of the resin significantly decreased. Significant differences were observed in power and resin hardness among the PE0, PE1, and PE3 groups. When the duration of usage was 6 months or less, only multi-layered PE films led to a significant increase in the percentage decrease of hardness of cured resin from top to bottom. However, at 12 months, both single-layer and multi-layered PE films resulted in a significant increase in the percentage decrease of hardness of cured resin from top to bottom.

Conclusion

The output power of the light curing unit decreases with prolonged usage, thereby failing to meet the curing requirements of Bulk Fill composite resin. The use of single-layer PE as an infection control barrier is recommended.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Composite ResinsCuring Lights, DentalHardnessMaterials TestingTime FactorsLight-Curing of Dental AdhesivesPolyethylene

Stichwörter der Autor:innen

Bulk Fill composite resinHardnessLight curing unitPower

Substanzen

Composite ResinsPolyethylene

Autor:innen und Institutionen

  • Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, zheji…

ORCID-Profile: Denghui Zhang

Förderung

  • Key R&D program of Zhejiang
  • General Research Project of Zhejiang Provincial Department of Education

Zitieren

APA

He, X., Zhang, D., & Deng, S. (2024). Effect of duration and infection control barriers of light curing unit on hardness of Bulk Fill composite resin. PeerJ. https://doi.org/10.7717/peerj.18021

Vancouver

He X, Zhang D, Deng S. Effect of duration and infection control barriers of light curing unit on hardness of Bulk Fill composite resin. PeerJ. 2024. doi:10.7717/peerj.18021

BibTeX
@article{He2024,
  author = {He, Xinmin and Zhang, Denghui and Deng, Shuli},
  title = {Effect of duration and infection control barriers of light curing unit on hardness of Bulk Fill composite resin},
  journal = {PeerJ},
  year = {2024},
  doi = {10.7717/peerj.18021}
}
Kostenlos starten →