EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Wearable accelerometers reveal objective assessment of walking symmetry and regularity in idiopathic scoliosis patients

Xiaopeng Gan, Xin Liu, Danxian Cai, Rongbin Zhang, Fanqiang Li, Haohuang Fang, Jingrou Huang, Chenguang Qiu, Hongrui Zhan

PeerJ · 16.07.2024 · 12 · e17739

DOI: 10.7717/peerj.17739 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PeerJ, online erschienen am 16.07.2024. Verfasst von Xiaopeng Gan und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation Medicine, The Fifth Affiliated Hospital of Sun Yat-sen University, Zhuhai, China. Hauptthemen laut MEDLINE: Scoliosis, Accelerometry, Walking, Gait. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fifth Affiliated Hospital of Sun Yat-sen University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Scoliosis is a multifaceted three-dimensional deformity that significantly affects patients’ balance function and walking process. While existing research primarily focuses on spatial and temporal parameters of walking and trunk/pelvic kinematics asymmetry, there remains controversy regarding the symmetry and regularity of bilateral lower limb gait. This study aims to investigate the symmetry and regularity of bilateral lower limb gait and examine the balance control strategy of the head during walking in patients with idiopathic scoliosis.

Methods

The study involved 17 patients with idiopathic scoliosis of Lenke 1 and Lenke 5 classifications, along with 17 healthy subjects for comparison. Three-dimensional accelerometers were attached to the head and L5 spinous process of each participant, and three-dimensional motion acceleration signals were collected during a 10-meter walking test. Analysis of the collected acceleration signals involved calculating five variables related to the symmetry and regularity of walking: root mean square (RMS) of the acceleration signal, harmonic ratio (HR), step regularity, stride regularity, and gait symmetry.

Results

Our analysis reveals that, during the walking process, the three-dimensional motion acceleration signals acquired from the lumbar region of patients diagnosed with idiopathic scoliosis exhibit noteworthy disparities in the RMS of the vertical axis (RMS-VT) and the HR of the vertical axis (HR-VT) when compared to the corresponding values in the healthy control (RMS-VT: 1.6 ± 0.41 vs . 3 ± 0.47, P < 0.05; HR-VT: 3 ± 0.72 vs . 3.9 ± 0.71, P < 0.05). Additionally, the motion acceleration signals of the head in three-dimensional space, including the RMS in the anterior-posterior and vertical axis, the HR-VT, and the values of step regularity in both anterior-posterior and vertical axis, as well as the values of stride regularity in all three axes, are all significantly lower than those in the healthy control group ( P < 0.05).

Conclusion

The findings of the analysis suggest that the application of three-dimensional accelerometer sensors proves efficacious and convenient for scrutinizing the symmetry and regularity of walking in individuals with idiopathic scoliosis. Distinctive irregularities in gait symmetry and regularity manifest in patients with idiopathic scoliosis, particularly within the antero-posterior and vertical direction. Moreover, the dynamic balance control strategy of the head in three-dimensional space among patients with idiopathic scoliosis exhibits a relatively conservative nature when compared to healthy individuals.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ScoliosisAccelerometryWalkingGaitHumansFemaleAdolescentMaleBiomechanical PhenomenaWearable Electronic DevicesChildCase-Control StudiesPostural BalanceYoung Adult

Stichwörter der Autor:innen

Gait analysisScoliosisWalking stabilityWearable sensors

Autor:innen und Institutionen

  • Department of Rehabilitation Medicine, The Fifth Affiliated Hospital of Sun Yat-sen University, Zhuhai, China.

Förderung

  • Fifth Affiliated Hospital of Sun Yat-sen University

Zitieren

APA

Gan, X., Liu, X., Cai, D., Zhang, R., Li, F., Fang, H., Huang, J., Qiu, C., & Zhan, H. (2024). Wearable accelerometers reveal objective assessment of walking symmetry and regularity in idiopathic scoliosis patients. PeerJ, 12, e17739. https://doi.org/10.7717/peerj.17739

Vancouver

Gan X, Liu X, Cai D, Zhang R, Li F, Fang H, et al. Wearable accelerometers reveal objective assessment of walking symmetry and regularity in idiopathic scoliosis patients. PeerJ. 2024;12:e17739. doi:10.7717/peerj.17739

BibTeX
@article{Gan2024,
  author = {Gan, Xiaopeng and Liu, Xin and Cai, Danxian and Zhang, Rongbin and Li, Fanqiang and Fang, Haohuang and Huang, Jingrou and Qiu, Chenguang and Zhan, Hongrui},
  title = {Wearable accelerometers reveal objective assessment of walking symmetry and regularity in idiopathic scoliosis patients},
  journal = {PeerJ},
  year = {2024},
  volume = {12},
  pages = {e17739},
  doi = {10.7717/peerj.17739}
}
Kostenlos starten →