EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Accuracy of augmented reality-guided needle placement for pulsed radiofrequency treatment of pudendal neuralgia: a pilot study on a phantom model

Lars L Boogaard, Kim Notten, Kirsten Kluivers iD, Selina Van der Wal, Thomas J J Maal, Luc Verhamme

PeerJ · 2024

DOI: 10.7717/peerj.17127 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PeerJ, 2024. Verfasst von Lars L Boogaard und 5 weiteren Autor:innen. Beteiligte Einrichtung: Radboudumc 3D Lab, Radboud University Medical Centre, Nijmegen, The Netherlands. Hauptthemen laut MEDLINE: Pudendal Neuralgia, Pulsed Radiofrequency Treatment, Augmented Reality, Pudendal Nerve. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Pudendal neuralgia (PN) is a chronic neuropathy that causes pain, numbness, and dysfunction in the pelvic region. The current state-of-the-art treatment is pulsed radiofrequency (PRF) in which a needle is supposed to be placed close to the pudendal nerve for neuromodulation. Given the effective range of PRF of 5 mm, the accuracy of needle placement is important. This study aimed to investigate the potential of augmented reality guidance for improving the accuracy of needle placement in pulsed radiofrequency treatment for pudendal neuralgia.

Methods

In this pilot study, eight subjects performed needle placements onto an in-house developed phantom model of the pelvis using AR guidance. AR guidance is provided using an in-house developed application on the HoloLens 2. The accuracy of needle placement was calculated based on the virtual 3D models of the needle and targeted phantom nerve, derived from CBCT scans.

Results

The median Euclidean distance between the tip of the needle and the target is found to be 4.37 (IQR 5.16) mm, the median lateral distance is 3.25 (IQR 4.62) mm and the median depth distance is 1.94 (IQR 7.07) mm.

Conclusion

In this study, the first method is described in which the accuracy of patient-specific needle placement using AR guidance is determined. This method could potentially improve the accuracy of PRF needle placement for pudendal neuralgia, resulting in improved treatment outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pudendal NeuralgiaPulsed Radiofrequency TreatmentAugmented RealityPudendal NerveHumansPilot Projects

Stichwörter der Autor:innen

AR guidanceAccuracyAugmented realityAugmented-reality applications in medicinePudendal neuralgiaPulsed radiofrequency

Autor:innen und Institutionen

  • Radboudumc 3D Lab, Radboud University Medical Centre, Nijmegen, The Netherlands.
  • Department of Obstetrics and Gynaecology, Radboud University Medical Centre, Nijmegen, The Netherlands.
  • Department of Anesthesiology, Pain and Palliative Care, Radboud University Medical Centre, Nijmegen, The Netherlands.

ORCID-Profile: Kirsten Kluivers

Zitieren

APA

Boogaard, L. L., Notten, K., Kluivers, K., Van der Wal, S., Maal, T. J. J., & Verhamme, L. (2024). Accuracy of augmented reality-guided needle placement for pulsed radiofrequency treatment of pudendal neuralgia: a pilot study on a phantom model. PeerJ. https://doi.org/10.7717/peerj.17127

Vancouver

Boogaard LL, Notten K, Kluivers K, Van der Wal S, Maal TJJ, Verhamme L. Accuracy of augmented reality-guided needle placement for pulsed radiofrequency treatment of pudendal neuralgia: a pilot study on a phantom model. PeerJ. 2024. doi:10.7717/peerj.17127

BibTeX
@article{Boogaard2024,
  author = {Boogaard, Lars L and Notten, Kim and Kluivers, Kirsten and Van der Wal, Selina and Maal, Thomas J J and Verhamme, Luc},
  title = {Accuracy of augmented reality-guided needle placement for pulsed radiofrequency treatment of pudendal neuralgia: a pilot study on a phantom model},
  journal = {PeerJ},
  year = {2024},
  doi = {10.7717/peerj.17127}
}
Kostenlos starten →