EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Consistency analysis of consciousness index and bispectral index in monitoring the depth of sevoflurane anesthesia in laparoscopic surgery

Miao Huo, Qian Zhang, Xingxing Zheng, Hui Wang, Ning Bai, Ruifen Xu, Ziyu Zhao

PeerJ · 2024

DOI: 10.7717/peerj.16848 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PeerJ, 2024. Verfasst von Miao Huo und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Shaanxi Provincial People's Hospital, Xi'an, China. Hauptthemen laut MEDLINE: Propofol, Anesthetics, Inhalation, Methyl Ethers, Laparoscopy. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The Index of Consciousness (IoC) is a new monitoring index of anesthesia depth reflecting the state of consciousness of the brain independently developed by China. The research on monitoring the depth of anesthesia mainly focuses on propofol, and bispectral index (BIS) is a sensitive and accurate objective index to evaluate the state of consciousness at home and abroad. This study mainly analyzed the effect of IoC on monitoring the depth of sevoflurane anesthesia and the consistency and accuracy with BIS when monitoring sevoflurane maintenance anesthesia.

Objective

To investigate the monitoring value of the Index of Consciousness (IoC) for the depth of sevoflurane anesthesia in laparoscopic surgery.

Methods

The study population consisted of 108 patients who experienced elective whole-body anesthesia procedures within the timeframe of April 2020 to June 2023 at our hospital. Throughout the anesthesia process, which encompassed induction and maintenance using inhaled sevoflurane, all patients were diligently monitored for both the Bispectral Index (BIS) and the Index of Consciousness (IoC). We conducted an analysis to assess the correlation between IoC and BIS throughout the anesthesia induction process and from the maintenance phase to the regaining of consciousness. To evaluate the predictive accuracy of IoC and BIS for the onset of unconsciousness during induction and the return of consciousness during emergence, we employed receiver operating characteristic (ROC) curve analysis.

Results

The mean difference between BIS and IoC, spanning from the pre-anesthesia induction phase to the completion of propofol induction, was 1.3 (95% Limits of Agreement [−53.4 to 56.0]). Similarly, during the interval from the initiation of sevoflurane inhalation to the point of consciousness restoration, the average difference between BIS and IoC was 0.3 (95% LOA [−10.8 to 11.4]). No statistically significant disparities were observed in the data acquired from the two measurement methodologies during both the anesthesia induction process and the journey from maintenance to the regaining of consciousness ( P > 0.05). The outcomes of the ROC curve analysis disclosed that the areas under the curve (AUC) for prognosticating the occurrence of loss of consciousness were 0.967 (95% CI [0.935–0.999]) for BIS and 0.959 (95% CI [0.924–0.993]) for IoC, with optimal threshold values set at 81 (sensitivity: 88.10%, specificity: 92.16%) and 77 (sensitivity: 79.55%, specificity: 95.45%) correspondingly. For the prediction of recovery of consciousness, the AUCs were 0.995 (95% CI [0.987–1.000]) for BIS and 0.963 (95% CI [0.916–1.000]) for IoC, each associated with optimal cutoff values of 76 (sensitivity: 92.86%, specificity: 100.00%) and 72 (sensitivity: 86.36%, specificity: 100.00%) respectively.

Conclusion

The monitoring of sevoflurane anesthesia maintenance using IoC demonstrates a level of comparability to BIS, and its alignment with BIS during the maintenance phase of sevoflurane anesthesia is robust. IoC displays promising potential for effectively monitoring the depth of anesthesia.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PropofolAnesthetics, InhalationMethyl EthersLaparoscopyHumansSevofluraneConsciousnessMonitoring, IntraoperativeAnesthesia, General

Stichwörter der Autor:innen

Anesthesia depthConsciousness indexLaparoscopic surgerySevoflurane

Substanzen

SevofluranePropofolAnesthetics, InhalationMethyl Ethers

Autor:innen und Institutionen

  • Department of Anesthesiology, Shaanxi Provincial People's Hospital, Xi'an, China.
  • Department of Burn and Plastic Surgery, Shaanxi Provincial People's Hospital, Xi'an, China.

Zitieren

APA

Huo, M., Zhang, Q., Zheng, X., Wang, H., Bai, N., Xu, R., & Zhao, Z. (2024). Consistency analysis of consciousness index and bispectral index in monitoring the depth of sevoflurane anesthesia in laparoscopic surgery. PeerJ. https://doi.org/10.7717/peerj.16848

Vancouver

Huo M, Zhang Q, Zheng X, Wang H, Bai N, Xu R, et al. Consistency analysis of consciousness index and bispectral index in monitoring the depth of sevoflurane anesthesia in laparoscopic surgery. PeerJ. 2024. doi:10.7717/peerj.16848

BibTeX
@article{Huo2024,
  author = {Huo, Miao and Zhang, Qian and Zheng, Xingxing and Wang, Hui and Bai, Ning and Xu, Ruifen and Zhao, Ziyu},
  title = {Consistency analysis of consciousness index and bispectral index in monitoring the depth of sevoflurane anesthesia in laparoscopic surgery},
  journal = {PeerJ},
  year = {2024},
  doi = {10.7717/peerj.16848}
}
Kostenlos starten →