Fachartikel in der Zeitschrift PeerJ, online erschienen am 17.03.2023. Verfasst von Aaron S Fox und 3 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Sport Research, School of Exercise and Nutrition Sciences, Deakin University, Geelong, Victoria, Australia. Hauptthemen laut MEDLINE: Gait, Running. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A common approach in the biomechanical analysis of running technique is to average data from several gait cycles to compute a ‘representative mean.’ However, the impact of the quantity and selection of gait cycles on biomechanical measures is not well understood. We examined the effects of gait cycle selection on kinematic data by: (i) comparing representative means calculated from varying numbers of gait cycles to ‘global’ means from the entire capture period; and (ii) comparing representative means from varying numbers of gait cycles sampled from different parts of the capture period. We used a public dataset ( n = 28) of lower limb kinematics captured during a 30-second period of treadmill running at three speeds (2.5 m s −1 , 3.5 m s −1 and 4.5 m s −1 ). ‘Ground truth’ values were determined by averaging data across all collected strides and compared to representative means calculated from random samples (1,000 samples) of n (range = 5–30) consecutive gait cycles. We also compared representative means calculated from n (range = 5–15) consecutive gait cycles randomly sampled (1,000 samples) from within the same data capture period. The mean, variance and range of the absolute error of the representative mean compared to the ‘ground truth’ mean progressively reduced across all speeds as the number of gait cycles used increased. Similar magnitudes of ‘error’ were observed between the 2.5 m s −1 and 3.5 m s −1 speeds at comparable gait cycle numbers —where the maximum errors were < 1.5 degrees even with a small number of gait cycles ( i.e. , 5–10). At the 4.5 m s −1 speed, maximum errors typically exceeded 2–4 degrees when a lower number of gait cycles were used. Subsequently, a higher number of gait cycles (i.e., 25–30) was required to achieve low errors (i.e., 1–2 degrees) at the 4.5 m s −1 speed. The mean, variance and range of absolute error of representative means calculated from different parts of the capture period was consistent irrespective of the number of gait cycles used. The error between representative means was low (i.e., < 1.5 degrees) and consistent across the different number of gait cycles at the 2.5 m s −1 and 3.5 m s −1 speeds, and consistent but larger ( i.e. , up to 2–4 degrees) at the 4.5 m s −1 speed. Our findings suggest that selecting as many gait cycles as possible from a treadmill running bout will minimise potential ‘error.’ Analysing a small sample (i.e., 5–10 cycles) will typically result in minimal ‘error’ (i.e., < 2 degrees), particularly at lower speeds (i.e., 2.5 m s −1 and 3.5 m s −1 ). Researchers and clinicians should consider the balance between practicalities of collecting and analysing a smaller number of gait cycles against the potential ‘error’ when determining their methodological approach. Irrespective of the number of gait cycles used, we recommend that the potential ‘error’ introduced by the choice of gait cycle number be considered when interpreting the magnitude of effects in treadmill-based running studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GaitRunningLower ExtremityExercise TestBiomechanical Phenomena

Stichwörter der Autor:innen

BiomechanicsGaitKinematicsMethodologyRunning

Autor:innen und Institutionen

  • Centre for Sport Research, School of Exercise and Nutrition Sciences, Deakin University, Geelong, Victoria, Australia.
  • University of Canberra Research Institute of Sport & Exercise (UCRISE), University of Canberra, Canberra, Australia.
  • Research & Enterprise, University of Canberra, Canberra, Australia.

Zitieren

APA

Fox, A. S., Bonacci, J., Warmenhoven, J., & Keast, M. F. (2023). Measurement error associated with gait cycle selection in treadmill running at various speeds. PeerJ, 11, e14921. https://doi.org/10.7717/peerj.14921

Vancouver

Fox AS, Bonacci J, Warmenhoven J, Keast MF. Measurement error associated with gait cycle selection in treadmill running at various speeds. PeerJ. 2023;11:e14921. doi:10.7717/peerj.14921

BibTeX
@article{Fox2023,
  author = {Fox, Aaron S and Bonacci, Jason and Warmenhoven, John and Keast, Meghan F},
  title = {Measurement error associated with gait cycle selection in treadmill running at various speeds},
  journal = {PeerJ},
  year = {2023},
  volume = {11},
  pages = {e14921},
  doi = {10.7717/peerj.14921}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche